Introduction, Preventive maintenance, Troubleshooting – Uniden PRO630XL User Manual

Page 4

Advertising
background image

UNIDEN Model PRO630XL

4

Preventive Maintenance:

The following system checks should be made every six to twelve months:

Check the Standing Wave Ratio (SWR).

Inspect the tightness of all electrical connections.

Inspect the antenna coaxial cable for wear or breaks on the shielding.

Inspect the tightness of all screws and other mounting hardware.

Troubleshooting:

Should the unit malfunction or perform poorly, follow these procedures:

If the transceiver is completely inoperative: Check the power cord and fuse.

If there is trouble with receiving: Check the VOLUME control setting. Be sure the SQUELCH is

adjusted properly. Possibly the radio is over-squelched.

If there is trouble with transmitting: Check that the transmission line (coaxial cable) is securely

connected to the ANTENNA connector. Check that the antenna is fully extended for proper

operation. Check that all transmission line (coaxial cable) connections are secure and free of

corrosion.

Blackening may occur on the Liquid Crystal Display if the AM CB Radio has been

subjected to extreme high temperature (above 60°C). This is not a fault. Normal

LCD operation resumes when the temperature stabilizes back to standard operating

condition (0-55°C).

Introduction

Advertising