Page 11, Operational summary – Universal Security Instruments MCND601CN User Manual

Page 11

Advertising
background image

Page 11

On and Blinks

off approx every

20 seconds

AC Power is present. DC power is present

Silent

Off and Blinks

on approx every

40 seconds

Off

Off

Alarm is powered by battery backup. AC Power is not
present. Check the breaker or fuse box for power. If the
breaker or fuse box looks normal, call a licensed
electrician for assistance.

1 beep,

1 second

pause,

4 beeps,

5 second

pause

Turns off

when the

4 beeps start

Blinks in

sync with

cycle of the

first beep

Blinks in

sync with

cycle of

4 beeps

The TEST button has been pressed. The test sequence
lasts for approximately 8 seconds after the button is
released.

4 beeps,

5 second

pause,

repeat

Off

Off

Blinks in

sync with

cycle of

4 beeps

Originating CO alarm - If a hazard is identified, please
take all precautions when an alarm sounds by calling an
Emergency Service and getting out of the home.

1 beep,

1 second

pause,

repeat

Turns off

when the

beeps start

Blinks in

sync with

the horn

Off

Originating Gas alarm - If a hazard is identified, please
take all precautions when an alarm sounds by calling an
Emergency Service and getting out of the home.

Horn sounds

when no

hazard is

present

On and blinks

off approx every

20 seconds

Blinks when

no hazard is

present

Blinks when

no hazard

is present

Nuisance Alarm - If there is no hazard present, verify the
alarm is mounted in the correct location (see User's
Manual, "AVOID THESE LOCATIONS" section). Reset
alarm as instructed below.

Silent

On and blinks

off approx every

20 seconds

Off

The CO Alarm Silence Feature is activated by pressing
and releasing the SILENCE button on the initiating alarm
while in alarm condition. The alarm will remain silent for
approx. 4 minutes, depending on the level of CO
detected. If CO levels drop below alarm levels, the alarm
will remain silent and return to normal operation. If CO
levels remain constant or increase, this indicates
potentially dangerous situation and the horn will sound
again. Ventilate area.

Off and

blinks on

approx every

10 seconds

until reset

Off

Off

POWER

GREEN LED

CO

RED LED

CONDITION OF ALARM AUDIBLE & VISUAL SIGNALS BEFORE SOLUTION / RECOMMENDATION

Silent

GAS

BLUE LED

HORN

OPERATIONAL SUMMARY

Silent

On and blinks

off approx

every

20 seconds

Off and

blinks on

approx every

10 seconds

until reset

Off

The Gas Alarm Silence Feature is activated by pressing
and releasing the SILENCE button on the initiating alarm
while in alarm condition. The alarm will remain silent for
a maximum of 20 seconds. If Gas levels drop below alarm
levels, the alarm will remain silent and return to normal
operation. If Gas levels remain constant or increase, this
indicates potentially dangerous situation and the horn
will sound again. Ventilate area.

CO Alarm Latching LED Indicator - The alarm has
previously detected CO and had alarmed. Follow the
reset instructions to remove the latching LED.

Off and

blinks on

approx every

5 seconds

until reset

Silent

On and blinks

off approx

every

20 seconds

Off

Gas Alarm Latching LED Indicator - The alarm has
previously detected Gas and alarmed. Follow the reset
instructions to remove the latching LED.

Off and blinks

on approx

every

5 seconds

until reset

1 beep,

1 second

pause,

4 beeps,

5 second

pause

Turns off when

the horn starts

Blinks in

sync with

the first beep

To reset the Alarm LED's, press the RESET button for 2
seconds. This will clear the Alarm LED's and clear the
Silence mode.
MCND-401CN and MCND601CN Series only: To reset
the peak CO memory, press and hold the RESET button
for 5 seconds until the peak level is cleared. The display
screen will display "000" when the peak CO level is reset
and then return to "- - -."

Blinks in

sync with

cycle of 4

beeps

3 chirps

approx every

20 seconds

Off

Off

Trouble/Service Alarm. Replace the alarm.

Off

2 chirps

approx every

20 seconds

Off

Off

End-of-Service Life Alarm. Replace the alarm.

Off

1 chirp

approx every

40 seconds

On and blinks

off approx

every

20 seconds

Off

Low Battery - Check to make sure the battery activation
pull tab has been completely removed, battery polarity is
correct and the battery terminals are making contact with
the alarm contacts in the battery compartment. If chirp
continues, replace the 9V battery.

Off

Silent

Off

Off

SOLUTION /

RECOMMENDATION

Advertising
This manual is related to the following products: