Installation of optional equipment, Installing domestic hot water coil – United States Stove Company 1800 User Manual

Page 26

Advertising
background image

INSTALLATION OF OPTIONAL EQUIPMENT

INSTALLING DOMESTIC HOT WATER COIL

1. Remove access panel at rear of enclosure.

2. With a utility knife cut out the section of fiberglass insulation

directly behind the access panel.

3. Remove cover plate from rear of firebox.

4. Place one nut on each end of the coil and thread each as

far as they will go.

5. Place the coil through the holes from the inside of the
firebox and run a washer and nut down each leg on the
outside of the stove. Before tightening the nuts down com-
pletely, wrap a piece of hi-temp fiberglass rope gasket,
provided with the kit, around each threaded leg between the
washer and the outside of the firebox. Tighten the nuts down
securely to insure an airtight installation. The installation is
now ready to be plumbed to your existing domestic hot water
system. Choose one of the three methods described in the
Hot Water Kit Installation Instructions.

6. Remove knockouts from access panel and attach to furnace

enclosure.

7. Have a qualified plumber connect your domestic hot water

pipe to the coil with appropriate fittings.

24

ACCESS
PANEL

REAR WALL OF FIREBOX

DOMESTIC HOT
WATER COIL

TURN INSIDE NUTS UP
TO END OF THREADS

1

4

2

1. NUT
2. WASHER
3. GASKET

5

3

6

Advertising
This manual is related to the following products: