14

2275ZWC & 2275ZWCOL

DANGER

ELECTROCUTION HAZARD
Never attempt to repair or perform maintenance on
the unit until the main electrical power has been
disconnected.

13

TROUBLESHOOTING GUIDE

PROBLEM

POSSIBLE CAUSE

REMEDY

Unit does not operate and
electronic display is blank.

No electrical supply

Plug unit in or check circuit breaker.

No interior light

Loose or burned out bulb

Tighten or replace bulb (See MAINTENANCE; LIGHT
BULB REPLACEMENT).

Electronic display is blank and
interior light is OFF with door OPEN.

Unit is in blackout lighting mode.

Exit blackout mode)
(See OPERATION; INTERIOR LIGHT CONTROL).

Electronic display is blank and
interior light is ON with door OPEN.

A display function has changed.

Touch and hold the left display warmer temperature
button and touch and release the POWER button three
times, then release the temperature button. The display
should become visible.

Electronic display shows repeating,
randomly flashing symbols and
partial characters.

A factory control mode has been
inadvertently entered.

Touch and hold the left display warmer temperature
button and touch and release the LIGHT button three
times, then release the temperature button to exit the
factory control mode. The set-point temperature should
now be displayed.

Electronic display shows:
0, 1 to 26, or 99.

A factory control mode has been
inadvertently entered.

Repeatedly touch the left display warmer temperature
button to advance any number shown to 99 and touch
and release the LIGHT button. The set-point
temperature should now be displayed.

Electronic display shows E3.

Door has been left open longer than
20 minutes.

Close door completely. The set-point temperature
should now be displayed.

Electronic display shows one or
more of the following:
E1, E2, E4, E5, E6, E7, E8, E9, E10, P1.

The unit is displaying an error code.

Record the error code(s) displayed and call for service.

Unit not cold enough. Check
temperatures (See OPERATION for
approximate temperatures).

Control set too warm

Set control to a cooler setting (See OPERATION;
ADJUSTING SET-POINT TEMPERATURE). Allow 24 hours
for temperature to stabilize.

Airflow to front grille blocked

Airflow must not be obstructed to front grille (See
OPERATION; CONDENSER CLEANING).

Dirty condenser coils

Clean condenser (See MAINTENANCE; CONDENSER
CLEANING).

Door gasket not sealing properly

Door adjustment required (See MAINTENANCE; DOOR
ALIGNMENT CHECK AND ADJUSTMENT).

Inaccurate temperature reading

Properly check temperature (See OPERATION;
CHECKING PRODUCT TEMPERATURE).

Unit is too cold. Check temperatures
(See OPERATION for approximate
temperatures)

Control set too cold

Set control to a warmer setting (See OPERATION;
ADJUSTING SET-POINT TEMPERATURE). Allow 24 hours
for temperature to stabilize.

The unit frosts up.

High ambient temperatures or
humidity

Defrost unit manually (See MAINTENANCE;
DEFROSTING).

Door gasket not sealing

Adjust door (See MAINTENANCE; DOOR ALIGNMENT
CHECK AND ADJUSTMENT).