NOTE:

Other appliances may also be used with the ElectroMate as long

as they do not exceed the 30 ampere DC limit of the units’

cigarette lighter type socket or the 1800 watt AC limit of the

power inverter. Call Vector toll-free (866) 584-4446 for

information on Vector AC and DC appliances.

READ INSTRUCTION MANUAL AND PRODUCT LABELING CAREFULLY,

BEFORE USING THIS PRODUCT. FOLLOW RECOMMENDED WARNINGS,

CAUTIONS, SAFETY PROCEDURES AND MANUFACTURER’S

GUIDELINES FOR YOUR VEHICLE BATTERY.

IMPORTANT:

This unit is delivered without a battery. The user must

install a “Group 27” battery and assume that the battery is

partially charged. You must then connect the battery charger and

fully charge the battery before using the system. The battery must

be a “Group 27”, sealed lead acid battery with terminals on top;

otherwise the battery may not fit in the battery compartment.

These batteries have a range of 85 to 125 Ampere Hour

capacity. See Appendix A for Battery Installation information.

3. Using ElectroMate™ as a Jump-Start System

Read all Warnings, Cautions and Notes carefully before using this

unit. Read and understand all WARNINGS and CAUTIONS printed

at the front of this manual.

3.1

Jump-start Procedure

1. Make sure the ElectroMate Safety Switch is turned OFF, enabling the

reverse polarity alarms and correct polarity indicator.

2. Turn Off ignition and all accessories (radio, A/C, lights, etc.). Place

vehicle in “park” and set the emergency brake.

3. Observe jump-starting negative or positive ground system, as follows:

Negative ground (negative battery terminal connected to chassis) -

most common.

4. Carefully unwrap the cables from the storage area starting at clamps.

5. Connect positive (+) red clamp to vehicle’s positive battery terminal.

6. Connect negative (-) black clamp to chassis or a solid, non-moving, metal

vehicle component or body part - never clamp directly to negative battery

terminal or moving part.

7. If polarity is correct the POLARITY CORRECT LED will light. If the polarity

is incorrect, the audible REVERSE POLARITY ALARM will sound and the

LED will light.

WARNING:

IF REVERSE POLARITY ALARM SOUNDS, DO NOT TURN ON

SAFETY SWITCH. REVERSE THE POSITION OF THE CLAMPS AND

OBSERVE POLARITY LEDS. IF POLARITY CORRECT LED LIGHTS,

THEN TURN ON THE SAFETY SWITCH.

8. Start vehicle (crank engine in 3 - 5 second bursts). If engine won’t start,

seek help and go to step 10.

9. Leave engine running.

10. Turn OFF the Safety switch.

11. Remove clamps (disconnect the negative (black) clamp first; followed by

the positive (red) clamp) and store cables and clamps.

12. Recharge ElectroMate as soon as possible.