Operating heater, Inspecting burner, Manual lighting procedure – Vanguard Heating VP2000BB User Manual

Page 19

Advertising
background image

19

100100

TO TURN OFF GAS TO APPLIANCE

OPERATING

HEATER

Continued

Shutting Off Heater

1. Turn control knob clockwise

Clockwise

to the PILOT position.

2. Press in control knob and turn clockwise

Clockwise

to the OFF position.

3. Turn off all electric power to the appliance if service is to be performed.

Shutting Off Burner Only (pilot stays lit)

1. Turn control knob clockwise

Clockwise

to the PILOT position.

MANUAL LIGHTING PROCEDURE

1. Remove front panel (see Figure 6, page 11).
2. Follow steps 1 through 5 under Lighting Instructions
, pages 17 and 18.
3. With control knob pressed in, strike match. Hold match to pilot until pilot

lights.

4. Keep control knob pressed in for 30 seconds after lighting pilot. After 30

seconds, release control knob.

5. Replace front panel.

INSPECTING

BURNER

Check pilot flame pattern and burner flame pattern often.

PILOT FLAME PATTERN

Figure 18 shows a correct pilot flame pattern. Figure 19 shows an incorrect pilot
flame pattern. The incorrect pilot flame is not touching the thermocouple. This will
cause the thermocouple to cool. When the thermocouple cools, the heater will shut
down.

GRH/OV 007

GOOD PILOT/LP

Figure 18 - Correct Pilot Flame Pattern

Pilot Burner

Thermocouple

Figure 19 - Incorrect Pilot Flame Pattern

GRH/OV 008

BAD PILOT/LP

Thermocouple

Pilot Burner

Continued