Setup the test equipment, Rf unit test & alignment points, Pll vcv – Vertex Standard VX-3200V User Manual

Page 12: Pll reference frequency, Alignment

Advertising
background image

12

Alignment

Setup the test equipment as shown below, apply 13.6V

DC power to the transceiver.
The transceiver must be programmed for use in the in-

tended system before alignment is attempted. The RF pa-

rameters are loaded from the file during the alignment

process.

Important

In order to facilitate alignment over the complete switch-

ing range of the equipment it is recommended that the

channel data in the transceiver is preset as the chart be-

low.

The alignment mode is accessed by “Alignment mode”

command from the computer whilst switching on. And it

is operated by the alignment tool automatically.
During the alignment mode, normal operation is suspend-

ed. Use the alignment tool program running on PC.

PLL VCV

¦

Connect the positive lead of the DC voltmeter to

the test point TP1007 (VCV) on the RF-Unit, as

indicated in the figure, and the negative lead to

chassis ground.

¦

Set the transceiver to the high band edge fre-

quency channel, then adjust coil L1016 on the

Unit for 7.25V on the voltmeter.

¦

Key the transmitter, and adjust coil L1017 on the

Unit for 7.25V on the voltmeter.

¦

Next select to the low edge frequency channel

and confirm above 2.00V to 3.00V on the volt-

meter.

¦

Key the transmitter, and confirm above 2.00V to

3.00V on the voltmeter.

PLL Reference Frequency

With the wattmeter, dummy load and frequency counter

connected to the antenna jack, and select band center fre-

quency channel, key the transmitter and adjust VR1001

on the RF-Unit, if necessary, so the counter frequency is

within 100 Hz of the channel center frequency for the trans-

ceiver version.

Transceiver

RF Unit Test & Alignment Points

L1016

L1017

VR1001

TP1007

C

HANNEL

CH 1
CH 2
CH 3
CH 4

C

HANNEL

S

PACE

W ide

Narrow

W ide
W ide

Version A

147.100 MHz
147.100 MHz
134.100 MHz
159.900 MHz

Version D

161.100 MHz
161.100 MHz
148.100 MHz
173.900 MHz

F

REQUENCY

(S

IMPLEX

)

Advertising