Service procedures, Warning – Vanguard Heating GVB35P User Manual

Page 30

Advertising
background image

30

100354

SERVICE

PROCEDURES

Removing Control Valve
and Burner Tube

1. Shut off gas supply to

heater.

2. Remove lower front

access panel on heater.

3. Disconnect burner tube

from orifice holder (see
Figure 22).

4. Remove pilot gas line

from control valve (see
Figure 22).

5. Disconnect wire connec-

tors from thermocouple
interrupter (see Figure
22).

6. Remove thermocouple

and thermocouple inter-
rupter from control valve.

7. Remove cotter pin from

control valve. This
releases the control rod
from valve (see Figure
22).

8. Remove the two mounting

screws from control valve
mounting bracket (see
Figure 22).

9. Remove assembly from

the rear of heater.

10. To reinstall, reverse above

steps. Turn on gas to
heater and check for gas
leaks. Apply a mixture of
liquid soap and water to
all joints. Bubbles forming
show a leak. Correct all
leaks at once.

11. Replace lower front

access panel.

Figure 22 - Removing Control Valve and Burner Tube

Wire Connector

Control Valve
Bracket

Cotter Pin

Control Valve

Control Rod

Thermocouple
Interrupter

Burner
Tube

Orifice
Holder

Mounting
Screw

Wire Connector

Pilot Gas Line

Thermocouple

WARNING

Turn off and unplug heater and let cool before servicing.
Unless you need gas supply for testing, shut off manual
shutoff valve before servicing. Only a qualified service
person should service and repair heater and venting
system.

Advertising
This manual is related to the following products: