Vinotemp WINE-MATE VINO-2500SSR User Manual

Page 2

Advertising
background image

- 1 -

CAUTION:
DO NOT SWITCH ON THE COMPRESSOR IF THE CONDENSING UNIT IS
EQUIPPED WITH A LOW AMBIENT CONDITION KIT UNTIL THE UNIT HAS
BEEN PLUGGED IN FOR 24 HOURS.

2. Valve Operation (Condensing unit)

BACK POSITION FRONT POSITION MIDDLE POSITION

Fig. 4 ROTALOCK Valve Operation

BACK POSITION FRONT POSITION MIDDLE POSITION

Fig. 5 Base Valve Operation

1 - Process & Manometer; 2 - Receiver/Compressor Suction
3 - Liquid/Suction Line; 4 - Pressure Control

Back Position: Process and manometer port closed for normal operation
Front Position
: Connection to liquid or suction line closed
Middle Position: All ports open for evacuation, charge and manometer reading


3. Evaporator Unit

• The WM25-45SFCR evaporator units shall be installed for rack mount with

the air supply from the left front, top or side and air return on the right
front, top or side.

• Supply and return air flow from the evaporator unit shall be unobstructed

for at least 1 foot.

Advertising
This manual is related to the following products: