Page 4: Safety information, Continued, Figure 1 - firebox front view

Advertising
background image

www.desatech.com

105604-01H

4

5. Vent-free gas log heaters installed in these

fireboxes require fresh air ventilation to run

properly. See Air for Combustion and Ventila-

tion, page 6.

6. Do not run firebox

• where flammable liquids or vapors are used

or stored

• under dusty conditions

7. Do not use this firebox to cook food or burn

paper or other objects.

8. Turn firebox off and let cool before servicing.

Only a qualified service person should service

and repair firebox.

9. Operating vent-free log sets in a firebox

above elevations of 4,500 feet could cause

pilot outage.

10. Do not use the firebox if it has been under

water due to the shock hazard that could

result with the blower accessary (if installed)

in place.

11. Provide adequate clearances around air

openings.

LOCAL CODES

Install and use fireplace with care. Follow all local

codes. In the absence of local codes, use the latest edi-

tion of The National Fuel Gas Code ANSI Z223.1/

NFPA 54*. Firebox must be electrically grounded

in accordance with the National Electrical Code,

ANSI/NFPA70 (latest edition).
*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

UNPACKING

1. With utility knife, cut the carton all the way

around above the staples on the bottom tray.

Lift the carton off the firebox. Remove pack-

ing. Note: The hood is located in the packing

on the right hand side of the heater front. Lift

the heater off the bottom tray.

SAFETY INFORMATION

Continued

2. Check carton contents for the following:

• Screen assembly (2)

• Screen support rod (2)

• Hood

• Hardware and parts bag containing the

following:

• Ownerʼs Operation and Installation

Manual

• 2 - Black #10 x 3/8” Phillips screws

• 3 - Zinc #10 x 1/2” shouldered hex

screws

• 2 - Black #10 x 5/8” shouldered hex

screws

If any items are missing, inform dealer where

you bought the firebox.

3. Check all items for any shipping damage. If

damaged, promptly inform dealer where you

bought firebox.

PRODUCT

SPECIFICATIONS

Figure 1 - Firebox Front View

35

1

/

16

"

31

3

/

4

"

16

1

/

4

"

1

1

/

4

"

2

3

/

4

"

2

3

/

4

"

6

3

/

8

"

19

3

/

8

"

3

7

/

8

"

6

3

/

4

"

Built-in Nailing
Flanges

Standoffs (Models
FB32NCA and
NLFB32NC only)

Louvers (Models FB32CA
and NLFB32C only)

Advertising