1. Condensing Unit

• Place the condensing units WM150-650SCU in a

properly ventilated location. If it is not, heat exhausted
by the condensing unit will build up and the cooling
system will not operate properly.

• Condensing unit shall be elevated to avoid possible flooding and shaded

from direct sun. It shall not be exposed to temperatures higher than 110

°

F or lower than 50

°

F (optional low ambient kit available).

• Leave minimum 5 feet clearance for the exhaust side and leave minimum

1 foot clearance for the fresh air intake side.

CAUTION:
DO NOT SWITCH ON THE COMPRESSOR IF THE CONDENSING UNIT IS
EQUIPPED WITH A LOW AMBIENT CONDITION KIT UNTIL THE UNIT HAS
BEEN PLUGGED IN FOR 24 HOURS.


2. Valve Operation (Condensing unit)

BACK POSITION FRONT POSITION MIDDLE POSITION

Fig. 6 ROTALOCK Valve Operation

BACK POSITION FRONT POSITION MIDDLE POSITION

Fig. 7 Base Valve Operation

1 - Process & Manometer; 2 - Receiver/Compressor Suction
3 - Liquid/Suction Line; 4 - Pressure Control