Vector START-IT VEC011 User Manual

Page 6

Advertising
background image

7

Battery Disposal

Contains a maintenance-free, sealed, non-spillable, lead acid
battery, which must be disposed of properly. Recycling is
required — contact your local authority for information. Failure
to comply with local, state and federal regulations can result in
fines or imprisonment. For more information on recycling this
battery, call toll-free (800) 822-8837.

WARNINGS

Do not dispose of the battery in fire, as this may result in an explosion.

Before disposing of the battery, protect exposed terminals with
heavy-duty electrical tape to prevent shorting (shorting can result in
injury or fire).

Do not expose battery to fire or intense heat, as it may explode.

TROUBLESHOOTING

Unit Fails to Jump-Start

• Make sure unit’s power switch is in the ON position.
• Check that Jump-Starter has a full charge.
• Make sure a proper polarity cable connection has been established (see “Using

the Unit as a Jump-Starter,” page 3).

12 Volt Outlet Fails to Deliver Power

• Make sure a proper 12 volt adapter connection has been established.
• Check that Jump-Starter has a full charge.

12 Volt Outlet Shuts Off

Disconnect unit and allow to cool for 10 minutes.

Note:

When drawing more than 12 amps from the 12 volt outlet, unit will shut off.

Worklight Does Not Come On

• Check that Jump-Starter has a full charge.

SPECIFICATIONS

Jump-Start Clamps:

300 amps – heavy-duty copper

Jumper Cables:

#6AWG welding cable

Peak Amps:

600

Boost Amps:

300

Battery High Density AGM:

12 volt, 9 Ah, sealed lead-acid

Worklight Bulb:

12 volt 100 mA festoon type

DC Accessory Outlet

Protection:

12 amps self-resetting breaker

6

4. When charging is completed, remove the charging cord and store in a safe place.

Make sure ON/OFF Safety Switch and Worklight are turned OFF during 12 Volt
DC Recharge as this may slow the process.

Note:

The DC recharge method will recharge the unit’s battery, but the green LED
may not light if the charging source is below 12.6 volts. AC recharge is the
recommended method.

WARNINGS

• DO NOT EXCEED 3 HOURS MAXIMUM OF CHARGING TIME USING

THE 12 VOLT DC METHOD.

• NEVER leave unattended while DC charging.

Replacement Parts

For replacement parts (bulbs, batteries, charging adapters, etc.), contact Vector
Technical Support: toll free (866) 584-5504. There are no user serviceable parts
inside the unit. Periodically, the cables and connectors should be inspected for
damage, corrosion, dust, and dirt. If surfaces are dirty, they can be wiped clean
with a cloth moistened with water and a drop of detergent. Contacts can be wiped
clean with a dry cloth.

WARNING

Do not operate unit if there is any evidence of damage. The product
must be returned to manufacturer for testing and repair. Replace any
damaged charging adapters immediately before further use.

Bulb Replacement

You will need a small Phillips head screwdriver and a cartridge or festoon type, 12
volt 100 mA bulb.

1. Make sure the Worklight is turned OFF.
2. Remove the two Phillips type screws (turn counterclockwise).
3. Lift off the lens and set it aside.
4. Move one clip to free one end of the bulb .
5. Remove the bulb.

CAUTION

DO NOT USE ANY METAL TOOLS TO REMOVE OR REPLACE BULB

6. Snap the new bulb in place.
7. Snap lens in place and replace the 2 screws.
8. Turn screws clockwise to secure. NOT TO OVER-TIGHTEN.

Vec011_VW011_Manual_061005 6/16/05 12:12 PM Page 6

Advertising