What are the security system-call causes ?

See security chapter for more explanations.

Cause

Exter-
nal

fuse

Secu-
rity

system

In-
tern

al
fuse

Comment / solution

Over-tension (mains
provider)

X

X

Rare. Change the fuse. Unplug and
switch back on.

DC offset input

X
Back

LED:
on

Generally comes out source elements
such as CD players. Unplug all cables

but AC mains. Switch the appliance
back on. It must operate perfectly

alone. In that case, have your faulty
element fixed/repaired accordingly.
If the security LED stays on, while the
amplifier is only connected to AC mains

(with input XLR/RCA disconnected),
this indicates an internal failure. Please
contact your servicing contact point.

Appliance internal failure X

(or) X

The appliance alone does not operate.
Check if heat dissipaters are abnor-

mally hot.
Contact us

Shortcut on speakers

X

No output sound, or very low one,
which can sound bad while the appli-

ance is ON and the display is Normal.
Check the wiring and components

Replace the fuse

Output overload

X

No output sound, or very low one,
which can sound bad while the appli-

ance is ON and the display is Normal.
A too loud volume on low-impedance

speakers can result in such an over-
load.
Replace the fuse

Thermal runaway

X
Front

LED:
red

The amplifier puts itself in stand-by
mode (front LED red) if overheating.

Stop all music, and wait for the ampli-
fier to cool down. It will turn back to

normal operation (front LED green)
once the proper heat is reached. You

can switch it off to quicken the cooling.

Advertising