Block diagrams – Vector DA-250DH CU User Manual

Page 16

Advertising
background image

16

H
C

CH 1 INPUT

E

H
C

CH 2 INPUT

E

Current Limiter

Short Detector

Protection Circuit

OUTPUT 1

relay

CH 1
OUTPUT

CH 2
OUTPUT

+4 dB

-10 dB

CH 1 sensitivity
selection jumper
(+4 dB/-10 dB)

CH 1
input level
control

+4 dB

-10 dB

CH 2 sensitivity
selection jumper
(+4 dB/-10 dB)

CH 2
input level
control

ON

OFF

BRIDGE ON/OFF switch

+
-

BRIDGE
OUTPUT

Current Limiter

Short Detector

Protection Circuit

OUTPUT 2

relay

+
-

PARALLEL
switch

14. BLOCK DIAGRAMS

14.1. DA-250D

14.2. DA-250DH

PARALLEL
switch

OFF

ON

CH 2 HPF
ON/OFF jumper

HPF
50 Hz

H
C

CH 1 INPUT

E

H
C

CH 2 INPUT

E

Current Limiter

Short Detector

Protection Circuit

OUTPUT 1

relay

CH 1
OUTPUT

CH 2
OUTPUT

+4 dB

-10 dB

CH 1 sensitivity
selection jumper
(+4 dB/-10 dB)

CH 1
input level
control

+4 dB

-10 dB

CH 2 sensitivity
selection jumper
(+4 dB/-10 dB)

CH 2
input level
control

ON

OFF

BRIDGE ON/OFF
switch

+
-

BRIDGE
OUTPUT

Current Limiter

Short Detector

Protection Circuit

OUTPUT 2

relay

+
-

OFF

ON

CH 1 HPF
ON/OFF jumper

HPF
50 Hz

Advertising