INSTALLER/CONFIGURATION MENU

Thermostat must be in Heat, Cool or Auto. Press and hold the Menu button for at least 5 seconds. The display will show item
#1 in the table below. Press Menu to advance to the next menu item. Press

or

to change a menu item options.

INSTALLER/CONFIGURATION MENU

Menu

Ref.

HP SS

Press

Button

Displayed

(Factory Default)

Press

or

to select from listed

options

Comments

1

1

1

MENU

(MS 2)

HP 1, HP 2, SS 1

Selects Multi-Stage (MS 2 No Heat Pump),

Heat Pump 1 (HP 1, 1 compressor),

Heat Pump 2 (HP 2, 2 compressor or 2

speed compressor), or Single Stage (SS 1)

2

2

2

MENU

(GAS) for SS or MS

(ELE) for HP

ELE

GAS setting: furnace controls the blower
ELE setting: thermostat controls the blower

3

3

3

MENU

CS (3)

0, 1, 2, 4, 5, 6

Selects Cool Savings

Value 1 (low) to 6 (high),

Value 0 disables feature

4

4

4

MENU

E (On)

OFF

Selects Energy Management Recovery (EMR)

On or OFF.

5

5

MENU

CR Heat (ME)

SL, FA

Selects Adjustable Anticipation, cycle rate, Heat

(This item only appears when MS 2 or SS 1 is

selected above)

6

5

MENU

CR Heat Pump

(ME)

SL, FA

Selects Adjustable Compressor Anticipation

(Heat Pump) This item only appears when

HP 1, HP 2 is selected above

7

6

6

MENU

CR Cool (ME)

or

CR AU (FA)

SL, FA

SL

Selects Adjustable Anticipation, cycle rate, cool

(when MS 2 or SS 1 is selected above.) or

Selects the cycle rate for Auxiliary stage (when

HP 1 or HP 2 is selected above)

8

7

7

MENU

CL (OFF)

CL On

Compressor Lockout Time

9

8

8

MENU

Em Heat, Auto

Cool Off

or

Heat, Auto,Cool Off

Heat Cool Off,

Heat Off with Fan icon,

Heat Off without Fan icon

Cool Off, Auto Off

System Mode Confi guration

with Automatic Changeover capability

10

9

9

MENU

dL (On)

dL OFF

Selects Display Light On or OFF

11

10

10

MENU

0

(current temperature)

1 HI, 2 HI, 3HI, 4 HI,

1 LO, 2 LO, 3 LO, 4 LO

Adjustable Ambient Temperature Display

12

11

11

MENU

°F

°C

Selects Fahrenheit/Celsius Temperature Display

13

12

12

MENU

(On) b

OFF

May select Beeper OFF to stop audible

key feedback

14

13

13

MENU

P (7)

3, 0

Defaults 7-day programming (P7) but non-

programmable (0) or 5/1/1 programming (P3)

is available on most models.

15

14

14

MENU

PS (4)

2

Selects Program periods per day:

4 = Morn, Day, Eve, Night

2 = Day, Night

16

15

15

MENU

Heat AS (On)

OFF

Automatic Schedule for heat mode

17

16

16

MENU

Cool AS (On)

OFF

Automatic Schedule for cool mode

18

17

MENU

Heat FA (On)

OFF

Fast Heat option may be disabled by

selecting OFF. NA to SS or HP1 confi g.

19

18

MENU

Cool FA (On)

OFF

Fast Cool option may be disabled by

selecting OFF. NA to SS or HP1 confi g.

20

19

17

MENU

Remote (OFF)

On

Selects Remote Sensor On/OFF

MENU

Remote

(In)

Outdoor

Selects Remote Sensor to outdoor

NA is Remote Sensor OFF

MENU

Indoor Loc

(On)

OFF

Selects Local Sensor (in thermostat) to OFF.

N/A if Remote is selected to Outdoor

Advertising