Wegener Communications Unity RF Switch User Manual

Page 3

Advertising
background image

Page 3

Page 3 of 6

800016-13

B. INSTALL THE RF SWITCH

See

Figure 1

(Page 5) and

Figure 2

(Page 5) of this guide for views of the module and its

installation.

1. Remove the block-out plate from the Module where the switch is to be installed.

These screws and holes will be used to mount the RF Switch in a later step. Use the
#1 Philips Screwdriver for this.

2. From the inside of the unit, install the RF Switch into position. The “F” Connectors

should protrude through the rear panel

3. Install one (1) self-tapping screw through the RF Switch Printed Wiring Board

(PWB) into the hole in the bottom of the chassis. Leave it loose at this time. Only
one screw will be used in this step, and which hole is used will depend on the module
slot. This self-tapping screw “cuts” its own threads in the standoff hole, and may
require moderate effort to turn it.

4. Line up the two holes in the rear of the RF Switch Bracket with the holes mentioned

in Step # B1. Insert the self-tapping screws retained in Step # B1 through the receiver
rear panel into the RF Switch Bracket. Tighten these screws snugly, but do not
overtighten.

5. Tighten the Screw inserted in Step # B3 at this time. Do not overtighten.

6. Connect the supplied 10-pin cable from J1 on the RF Switch PWB to the appropriate

connector on the receiver motherboard. If there is a cable from the RF Switch
Expansion Bus to another board (either the Tuner Board or a Relay Board), note its
location and remove that cable. Connect the middle connector of the new cable to the
same connector on the previously installed Board.

7. On most units, the motherboard connector will be labeled “RF Switch Expansion

Bus” or “Relay Expansion Bus,” and should have a number beside it corresponding to
the number in the following table. See

Table 1

, below, for the various models. Make

sure Pin 1 (the Red Line) on each cable connector goes to Pin 1 on each board
connector. If you have any questions about this, contact system network control or
Wegener Customer Service at 770-814-4057. Additional numbers are shown on the
rear cover of this installation guide.

Table 1. Receiver Models and RF Switch Expansion Bus Connector Numbers

Receiver Model

Connector Number

UNITY401R

J7

UNITY500

J11

UNITY4000

J11

UNITY4422

J16

UNITY5000

J49

Advertising