Wolf Appliance Company PI423418(R) User Manual

Page 5

Advertising
background image

5

Dimensions in parentheses are in
millimeters unless otherwise specified.

Planning Information

Pro Island Ventilation Hood

M O D E L P I 4 2 3 4 1 8 ( R )

I N S T A L L A T I O N N O T E S

Refer to the illustrations and specifications

for overall dimensions and installation specifics.

Wolf Pro island ventilation hoods are recom-

mended for use with any Wolf cooking appli-
ance. The hood must overlap the cooking
surface by a minimum of 3" (76) on either side.

Installation of all Pro ventilation hoods

should be 30" (762) to 36" (914) from the
bottom of the hood to the countertop. Follow
the dimensions shown in the Installation
illustration on page 4.

Wolf Pro island hoods are shipped without a

blower assembly. Internal, in-line or remote
blower assemblies are available. Blower options
also vary with the volume of air that needs to
be moved and the length of the duct run. Refer
to the charts at the end of this section for Pro
ventilation recommendations and blower
options.

IMPORTANT NOTE: Install this ventilation hood
only with a Wolf blower.

Pro island hoods require a separate,

grounded 110/120 V AC, 60 Hz power supply.
The service should have its own 15 amp circuit
breaker. Placement of the electrical supply is
not critical, as long as you provide enough 120
V AC, 60 Hz power cable to make the electrical
connection. Location of electrical is centered
through the top of the hood as shown in the
Installation illustration on page 4.

You must follow all National Electrical Code

regulations. In addition, be aware of local codes
and ordinances when installing your service.

Refer to the installation instructions shipped

with each Wolf product for detailed specifica-
tions. This information can also be found on
our website, wolfappliance.com.

Advertising