Caution, Maintenance instructions – Wells WPP-10 User Manual

Page 10

Advertising
background image

ADJUST STIRRER NEUTRAL POSITION

With the kettle switch OFF, the stirrer should land at a position that
allows the kettle to rotate without binding on the stirrer wand. If the
stirrer wand does not land positioned left to right, adjust the
positioning cam:

1. Disconnect unit from electric power. Remove the top panel.
Raise the kettle lid until it is captured by the magnetic holder.

2. Spin the gearmotor fan by hand until the stirrer wand is positioned
left to right (I.e. parallel to the front of the cabinet).

3. Loosen the positioning cam nut and locknut. Turn the cam until it
depresses the pin of the positioning switch. Tighten the cam nut
and lock nut.

4. Reconnect unit to electric power. Press the kettle switch to “ON”.
Wait approximately 5 seconds, then press the kettle switch to
“OFF”. The stirrer motor will run until the positioning cam activated
the positioning switch.

5. If the stirrer wand stops in the proper left-to-right position,
procedure is complete. Otherwise, repeat steps 1 through 4.

CHANGE HEAT LAMP

1. Press warmer switch “OFF”. Allow unit to cool before replacing
lamp.

2. Squeeze front and rear portions of guard until the front hook clears
the slot. Slide the rear hook from its slot, then remove the guard.

3.

Unthread old heat lamp from its socket and discard.

4.

Thread new heat lamp into socket.

IMPORTANT: Use only 400W safety-coated lamp

5. Reinstall guard.

CAUTION:

INJURY HAZARD

Disconnect appliance from
electrical power before
performing any of these
procedures.

Adjust Positioning Cam

CAUTION:

BURN HAZARD

Lamp may be hot.
Allow lamp to cool before
replacing

.

Change Heat Lamp

MAINTENANCE INSTRUCTIONS