MAINTENANCE

86041040 08/28/07

4-1

!

CAUTION

BRUSH ROLLER

To remove the brush roller, press the button and
turn the bearing downward.

Turn the brush slightly to the right and pull it out.











We recommend to regularly remove threads and
hair, which have been wound around the brush
roller.

FILTERS

When the orange bag full indicator is showing,
airflow is reduced. This could be because the
filter bag is full, the filters are clogged or there
may be a blockage.












CHANGING THE FILTER BAG

1. Remove the filter bag by opening the latch

on the side of the bag housing.

2. Close the filter bag with the sealing cap

and lift it out











The procedure to replace the bag is illustrated
on the front of each bag.
NOTE: You cannot close the bag housing if
the bag is fitted incorrectly.


CHANGING FILTERS

Motor Protection Filter
NOTE:
This filter can only be accessed by removing
the filter bag.

1. Lift the motor protection filter up by the

bracket.

2. Replace with new. NOTE: Make sure filter

fits in position tightly.

3. Put filter bag back in place.












The filter should be changed when it is dirty, at
minimum. No later then replacing 20 filter bags.

Exhaust Filter
NOTE:
Recommended to replace every time you
replace the Motor Protection Filter.

1. Carefully remove the filter retaining rings

and put them to the side.

2. Pull the enforcement strips of the filter out

of the housing slot.

3. Remove the filter from the housing.
4. Replace with new in reverse order.











Be sure the filter is fitted correctly in the housing
slot and retaining rings are installed correctly.
NOTE: If the filter is NOT installed correctly it will be
ineffective.

Use ONLY genuine Windsor
replacement parts to ensure

effectiveness and safety.

DO NOT wash any filters.