Whirlpool ADG 955 WHM User Manual

Page 3

Advertising
background image

S E R V I C E

Whirlpool Europe

ADG 955 WHM

19.03.1998 / Page 3

Customer Service

8542 955 10310

Doc. No: 4812 718 13129

Technical data

Flow rates / Inlet volume

Flow meter (at 0.3 bar
= quantity 1.1 l/min)

208

lmp/l

Spray pump

~ 70

l/min

Drain pump

16

l/min

Pump height max.

1.1

m

Inlet valve

4.5

l/min

Valve for Zone washing

30

l/min

Spray arm lower

33

l/min

Sprayarm upper

27

l/min

Ceiling rotor

10

l/min

Electrical data

Base data

Voltage

220/230

V

Frequency

50

Hz

Total power

2.0-2.2

kW

Fuse

10

A

Motor

Spray pump motor

Voltage

220/230

V

Power consumption

160

W

HI

81

HA

44

Capacitor

4

µ

F

Drain pump motor

Voltage

220/240

V

Power consumption

30

W

Resistance

146

Heating

1 Element system

Voltage

220/230

V

Power consumption

1.87/2.04 kW

Resistance

24.5

Heating speed

~ 2.0

˚C/min

Temperature on surface

~ 115

˚C

Safety thermostat
self reset

85

˚C

Potentiometer

Position 0

0.0

k

Position 1

0.5

k

Position 2

1.0

k

Position 3

1.4

k

Position 4

1.8

k

Position 5

2.3

k

Position 6

2.6

k

Water valves

Single valve at inlet hose

Voltage

220/240

V

Frequency

50/60

Hz

Resistance

3.76

k

Regenerating valve

Voltage

220/240

V

Frequency

50/60

Hz

Resistance

3.13

k

Valve for zone washing

Voltage

220-240

V

Frequency

50/60

Hz

Resistance

4

k

Coil of dispenser

Voltage

220/240

V

Frequency

50/60

Hz

Resistance

1.5

k

Reedcontact

flow meter
salt control

NTC

15 ˚C

75

k

20 ˚C

62

k

30 ˚C

43

k

40 ˚C

28

k

50 ˚C

19

k

60 ˚C

13

k

70 ˚C

9

k

80 ˚C

6

k

85 ˚C

5

k

Advertising