Spa troubleshooting, General operation troubleshooting guide, Problem probable causes solutions – Watkins C45S User Manual

Page 30

Advertising
background image

SPA TROUBLESHOOTING

If your spa doesn’t seem to be working the way you believe it should, please review the “START-UP” and “OPERATION” instructions in this manual. If this doesn’t help
you correct the problem, follow the appropriate instructions below. If the problem still is not resolved, call your Authorized dealer.

Priming the pump(s): Upon filling or refilling the spa, if a pump is operating and water is not flowing from any of its jets, the pump may not be
properly primed. To correct, perform the following procedures:
• Turn off power to the spa at the breaker and remove the equipment compartment door (see page 24).
• Loosen the union on the top of the pump(s) to allow the air to escape(see page 25). When water is present, hand-tighten the union.
• Turn power back on, activate the pump and check to make sure union is tight enough to keep it from leaking. Re-install equipment door.

27

GENERAL OPERATION TROUBLESHOOTING GUIDE

Entire spa is inoperative

Spa does not heat; jets and
light operate
(Display shows“ _._._._

_ ._._._”

Jets weak or surging

Spa does not heat; jets and
light operate
(Display shows “- - - -

- - - -”)

Light inoperative

• Power failure / not plugged in
• GFCI tripped

• Pressure switch is open and should be

closed

• Pressure switch senses flow through heater

even though the jet pump is off

• Spa water level too low
• Filters clogged / suction screens clogged
• Jet nozzles closed / Air valve closed

• Bad connection

• Heater high limit thermostat tripped

• System Controls

Display shows “- - - - “
(Entire spa inoperative)

• Check power source
• Reset GFCI; call for service if it will not reset.

• Check for clogged filter. The pressure switch will reset when the flow of

water through the heater has been restored. Call for service if the
pressure switch trips frequently.

• Contact an Authorized Service Technician

• Add water
• Clean filters / Clean suction screens
• Open jet nozzles / Open air valve

• Contact an Authorized Service Technician

• Disconnect power to the spa for at least thirty seconds to reset the

heater high-limit. If tripping continues, clean the filter, then if tripping still
occurs, call for service.

• Contact an Authorized Service Technician

Problem

Probable causes

Solutions

Water temperature
significantly different from
display temperature.
Display shows flashing
“READY” icon

Advertising
This manual is related to the following products: