4.2 Ribbon Sensor Calibration
Note: Please make sure the ribbon is properly installed before doing this
calibration.

Please follow the steps below to calibrate the ribbon sensor.
1. Turn the printer power off.
2. Press and hold the FEED button then turn on the printer.
3. The LED will turn orange then blink red 5 times. Release after the first red

blink and before the 5

rd

.

4. If the ribbon is properly installed the light will turn green. If it is not it will

turn red and blink.


4.3 Gap/Black Mark Calibration
Gap/black mark sensor sensitivity should be calibrated at the following
conditions:
1. A brand new printer
2. Change label stock
3. Printer initialization

Please follow the steps below to calibrate the sensor.
1. Turn the printer power off.
2. Press and hold the FEED button then turn on the printer.
3. The LED will turn orange, blink red 5 times and then blink orange 5 times.

Release after the first orange blink and before the 5

th

orange blink.


C

alibrating the gap/black mark sensor will measure the label length, print the

internal configuration and then enter dump mode.

The self-test printout can be used to check for dot damage on the print head
and can be used to check printer configurations and available memory space.

Turn the printer off and back on to resume normal printing.