Warnings and cautions, Installation instructions – Western Telematic PTS-8NE15-1 User Manual

Page 2

Advertising
background image

Warnings and Cautions:

Installation Instructions

Secure Racking

If Secure Racked units are installed in a closed or multi-unit rack assembly, they may require further

evaluation by Certification Agencies. The following items must be considered.

1. The ambient within the rack may be greater than room ambient. Installation should be such

that the amount of air flow required for safe operation is not compromised. The maximum

temperature for the equipment in this environment is 55°C. Consideration should be given to the

maximum rated ambient.

2. Installation should be such that a hazardous stability condition is not achieved due to uneven

loading.

Input Supply

Check nameplate ratings to assure there is no overloading of supply circuits that could have an effect

on overcurrent protection and supply wiring.

Grounding

Reliable earthing of this equipment must be maintained. Particular attention should be given to

supply connections when connecting to power strips, rather than direct connections to the branch

circuit.

No Serviceable Parts Inside; Authorized Service Personnel Only

Do not attempt to repair or service this device yourself. Internal components must be serviced by

authorized personnel only.

• Shock Hazard - Do Not Enter

Disconnect Power

If any of the following events are noted, immediately disconnect the unit from the outlet and contact

qualified service personnel:

1. If the power cord becomes frayed or damaged.

2. If liquid has been spilled into the device or if the device has been exposed to rain or water.

Two Power Supply Cables

Note that PTS Series units feature two separate power circuits, and a separate power supply cable for

each power circuit. Make certain to disconnect both power supply cables before attempting to service

or remove the unit.

15-Amp "Starter" Cable

Depending on your specific model, PTS Series units may be shipped with either one or two 125 VAC,

15 Amp "Starter" Cables. These Starter Cables will allow you to connect the PTS to power for bench

testing and initial start up and are adequate for applications that only require 15 Amps. For 20-Amp

power switching applications, please refer to the WTI Power Cable guide supplied with the unit, or

use appropriate 20-Amp cables.

Units with Attached Power Supply Cable(s)

For units with fixed Power Cords the socket-outlet shall be installed near the equipment and shall be

easily accessible.

Advertising
This manual is related to the following products: