Wolf Appliance Company CT15G/S User Manual

Page 5

Advertising
background image

Wolf gas cooktops are designed to operate

on natural gas at 5" (12.5 mb) WC (water
column) pressure or LP gas at 10" (25 mb) WC
pressure. The minimum line pressure for natural
gas is 7" (17.5 mb) WC and 11" (27.4 mb) WC
for LP gas. The maximum gas supply pressure
to the regulator should never exceed 14"
(34.9 mb) WC; .5 psi (3.5 kPa). It is supplied
with a

1

/

2

" NPT male gas connection at the

right rear bottom corner of the cooktop. The
male connector exits the unit straight down and
you are supplied with a regulator with two
female connectors.

You must follow all National Electrical Code

and gas regulations. In addition, be aware of
local codes and ordinances when installing your
services.

Wolf gas cooktops using natural gas

function up to an altitude of 8,000' (2438 m)
without any adjustment. Natural gas installa-
tions from 8,000' (2438 m) to 10,000' (3048 m)
need the high altitude conversion kit. LP gas
installations will operate up to 10,000' (3048 m)
without adjustment.

Refer to the installation instructions

shipped with each Wolf product for detailed
specifications.

Planning Information

Integrated Gas Cooktop

M O D E L C T 1 5 G / S

Dimensions in parentheses are in
millimeters unless otherwise specified.

5

I N S T A L L A T I O N N O T E S

Refer to the illustrations and specifications

for overall dimensions, cut-out dimensions and
installation specifics.

When multiple integrated cooktop modules

are installed side by side, refer to the counter-
top cut-out dimensions on page 6.

A Wolf downdraft system, Cooktop or

Pro ventilation hood is recommended. When
installing a ventilation hood, refer to the specific
requirements of the hood for the minimum
dimension to countertop. Also refer to the
ventilation recommendation charts in the
cooktop or Pro ventilation sections of our
website, wolfappliance.com.

The Wolf integrated gas cooktop requires a

separate 120 V AC, 60 Hz power supply. The
service should have its own 15 amp circuit
breaker and a grounded 3-prong receptacle
should be located within the reach of the
6' (1.8 m) power cord. Locate electrical within
the shaded area shown in the illustration on
page 4.

IMPORTANT NOTE: A ground fault circuit
interrupter (GFCI) is not recommended and may
cause interruption of operation.

For the integrated gas cooktop, the gas

service may be supplied through the floor if the
cooktop is not installed above an oven. Refer
to the illustration on page 4 for placement of
electrical and gas supply.

This cooktop is intended for indoor use only.

Advertising