Installation to Solid Concrete or Cinder Block

1

Make sure that tilt assembly (B) is level, use it as a
template to mark two mounting holes. Drill two 1/4"
(6 mm) dia. holes to a minimum depth of 2-1/2"
(64 mm). Insert anchors (C) in holes flush with wall
as shown (right). Place tilt assembly over anchors
and secure with two #14 x 2-1/2" screws (G). Level,
then tighten all fasteners.

• When installing Westinghouse wall mounts on cinder block, verify that you have a minimum of 1-3/8" of actual con-

crete thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount in a
solid part of the block, generally 1" minimum from the side of the block. Cinder block must meet ASTM C-90 specifica-
tions. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a hammer drill to
avoid breaking out the back of the hole when entering a void or cavity.

• Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.

• Make sure that the wall will safely support the combined load of the equipment and all attached hardware and

components.

WARNING

CUT

A

W

A

Y

VIEW

INCORRECT

concrete
surface

1

3

2

Drill holes and insert anchors (C).

CORRECT

Place assembly (B)

over anchors (C) and secure with screws (G).

Tighten all fasteners.

wall

plate

plaster/

dry wall

concrete

wall plate

concrete

plaster/

dry wall

• Always attach concrete expansion anchors directly to

load-bearing concrete.

• Never attach concrete expansion anchors to concrete

covered with plaster, drywall, or other finishing mate-
rial. If mounting to concrete surfaces covered with a
finishing surface is unavoidable, the finishing surface
must be counterbored as shown below. Be sure
concrete anchors do not pull away from concrete
when tightening screws. If plaster/drywall is thicker
than 5/8", custom fasteners must be supplied by
installer.

WARNING

B

• Tighten screws so that wall plate is firmly attached,

but do not overtighten. Overtightening can damage
screws, greatly reducing their holding power.

• Never tighten in excess of 80 in. • lb (9 N.M.).