Westinghouse High Efficiency / Direct Vent or Non Direct Vent FG6RL User Manual

Page 4

Advertising
background image

213B-0506 (Replaces 213B-0504)

Westinghouse products are manufactured and distributed by NORDYNE.

Approx. CFM
Airflow
@ 0.5" WC
12 = 1200
16 = 1600

FG

6

R

100

C

16

L

C = U.S. / Canada

Design Series

L =Downflow,

Condensing

Residential

Gas

Heating Input - Btuh
040 = 40,000
060 = 60,000
080 = 80,000
100 = 100,000
120 = 120,000

MODEL IDENTIFICATION CODE

B

Cabinet Width
A = 14 1/4
B = 19 3/4
C = 22 1/2

O'Fallon, MO

VENTING
All models are approved for vertical non direct (1 pipe) and direct (2 pipe) venting applications. See Vent Table below
for specified sizes and allowable lengths.

Before purchasing this appliance, read important energy cost
and efficiency information available from your retailer.
Specifications and illustrations subject to change without notice
and without incurring obligations. Printed in U.S.A. (05/06)

VENT TABLE

* NOTE:
1. Subtract 2.5 ft. for each

additional 2" elbow and 3.5 ft.
for each additional 3" elbow.

2. Two 45 degree elbows are

equivalent to one 90° elbow.

3. One short radius elbow is

equivalent to 2 long radius
elbows.

4. Do not include termination

elbows in calculation of vent
length.

5. This table is applicable for

elevations from sea level
to 2000 ft. For higher
elevations decrease vent pipe
lengths by 8% per 1000 ft. of
altitude.

6. Only the above pipe materials

are approved for use with FG6
Condensing Furnaces.

ACCESSORY VENT KITS

Kit

Description

2" PVC

3" PVC

4" PVC

Horizontal
Exterior Vent
Mounting Kit

9023730

9023750

9023760

Neutralizer Kit
(all models)

9023770

APPLICATION

SINGLE PIPE LENGTH (ft.)

DIRECT VENT, DUAL PIPE LENGTH (ft.)

with 1 long radius elbow**

with 1 long radius elbow on each pipe**

PVC,CPVC or ABS

Outlet

Outlet

Inlet/Outlet

Inlet/Outlet

Inlet/Outlet

SCH. 40 Pipe Size

2"

3"

2"

2"

3"

2"

3"

3"

80

150

40

40

50

50

90

90

Models 060 & 080

60

150

30

30

35

35

90

90

Models 100 & 120

30

150

15

15

25

25

90

90

Models 040

Kit

Order Number

U.S. LP Conversion Kit
(0 to 10,000 ft.)

904090A

Canadian LP Gas Conversion Kit
(0 to 4,500 ft.)

904091A

Fossil Fuel Kit

914762

Downflow Sub-Base A Cabinet

902974

B Cabinet

902677

C Cabinet

904108

Variable Speed Blower Kit
For "A" Cabinets

904231

Variable Speed Blower Kit
For "B" & "C" Cabinets

904075

Advertising