Install Vent System

1. Install exhaust hood. Use caulking compound to seal exterior

wall opening around exhaust hood.

2. Connect exhaust vent to hood. Vent must fit inside exhaust

hood. Secure vent to exhaust hood with vent tape.

3. Run exhaust vent to dryer location. Use the straightest path

possible. Avoid 90º turns. Use vent tape to seal all joints.

Install Leveling Legs

1. Remove tape from dryer cabinet. Open dryer door and

remove tape from dryer drum. (Not all dryer drums are

taped.) Remove drying rack, if included. Turn dryer drum

counterclockwise to make sure all tape was removed. Wipe

drum with damp cloth to remove any dust.

2. Take two cardboard corners from dryer carton and place

them on floor in back of dryer. Firmly grasp body of dryer and

gently lay it on its back on the cardboard corners.

diamond

marking

3. Start to screw legs into holes by hand. Use an adjustable

wrench or 1" (25 mm) hex-head socket wrench to finish

turning legs until you reach the ridge with the diamond

marking.

4. Place a carton corner post from dryer packaging under each

of the 2 dryer back corners. Stand the dryer up. Slide the

dryer on the corner posts until it is close to its final location.

Leave enough room to connect the exhaust vent.

Vent System Length

Maximum length of vent system depends upon the type of vent

used, number of elbows, and type of exhaust hood. The

maximum length for both rigid and flexible vent is shown in the

chart.

For vent systems not covered by the vent specification chart, see

Whirlpool Service Manual, “Exhausting Whirlpool Dryers,” Part

No. LIT603197, available from your Whirlpool parts distributor.

If dryer is installed in a confined area, such as a bedroom,

bathroom, or closet, provision must be made for enough

air for combustion and ventilation. (Check governing codes

and ordinances.) See “Recessed Area and Closet Installation

Instructions” in the “Location Requirements” section.

Number of

90° elbows

Type

of vent

Box/louvered

hoods

Angled

hoods

1

4

3

2

0

Rigid metal

Rigid metal

Rigid metal

Rigid metal

Rigid metal

64 ft. (20 m)

54 ft. (16.5 m)

44 ft. (13.4 m)

35 ft. (10.7 m)

27 ft. (8.2 m)

58 ft. (17.7 m)

48 ft. (14.6 m)

38 ft. (11.6 m)

29 ft. (8.8 m)

21 ft. (6.4 m)

Vent System Chart

12" min.

(305 mm)

12" min.

(305 mm)