Pro ventilation hood liner, Planning information – Wolf Appliance Company PL522212 User Manual

Page 6

Advertising
background image

6

Dimensions in parentheses are in
millimeters unless otherwise specified.

Planning Information

Pro Ventilation Hood Liner

M O D E L P L 5 2 2 2 1 2

Ducting for Pro ventilation
hood liners.

12"

(305)

HEIGHT OF LINER

HOOD LINER

DUCTWORK INSTALLATION

THROUGH ROOF

10" ROUND DUCT

SOFFIT OR CABINET

OR DUCT COVER

VERTICAL DISCHARGE ONLY FOR VENTILATION HOOD LINERS.

VERTICAL DISCHARGE

22

1

/

2

"

(572)

DEPTH OF LINER


DECORATIVE HOOD

30"

TO

36"

(762–914)

COUNTERTOP

TO BOTTOM OF

DECORATIVE HOOD

36"

(914)

STANDARD

FLOOR TO

COUNTERTOP

HEIGHT

TRANSITION

22

1

/

4

"W x 9"D

TO 10" ROUND 10"H

DIMENSIONS INCLUDE FLANGES

ROOF CAP OR REMOTE BLOWER

D U C T I N G C O N S I D E R A T I O N S

Wolf Pro hood liners are shipped without the

blower assembly. Internal, in-line and remote

blower assemblies are available.

IMPORTANT NOTE: Install this ventilation hood
liner only with a Wolf blower.

Pro hood liners have a vertical discharge location

with 10" (254) round duct. A transition with

backdraft damper is included. The hood liner will

operate most efficiently when ductwork does

not exceed 50' (15 m) in length.

Local building codes may require the use of

make-up air. Consult your local HVAC profes-

sional for specific requirements in your area.

IMPORTANT NOTE: Wolf Pro hood liners must

be vented to the outside. Use only metal

ductwork.

Refer to the illustration below for ducting

considerations for Pro ventilation hood liners.

Advertising