Wolf W302210I User Manual

Page 10

Advertising
background image

10

W O L F

P R O WA L L V E N T I L AT I O N

H O O D S

A C C E S S O R I E S

Optional acces-
sories are available
through your
Wolf dealer. To
obtain local dealer
information, visit
the Locator section
of our website,
wolfappliance.com.

L OW- P R O F I L E

A N D

2 4 " ( 6 1 0 )

H O O D S

S T E P 2 : W A L L P R E P A R A T I O N

Construct the wood wall framing flush with
the wall studs and centered in the location
that the hood will be mounted. Use the
rough-in plate shipped with hood to deter-
mine the location of the framing.

After the wall surface is finished, secure the
hood assembly to the wall.

Refer to the illustrations below for the location
of mounting holes for the low-profile and 24"
(610) deep wall hoods.

IMPORTANT NOTE: Wolf recommends
installing the internal blower to the rough-in
plate prior to mounting the hood.

If you are installing WBLOWER-60INT,
WBLOWER-90INT or WBLOWER-120INT,
refer to the internal blower information on
page 17 and follow installation instructions
provided with the blower.

The hood assembly is shipped with the
rough-in plate/transition attached. The
transition is shipped upside down in the top
of the hood. It must be removed and rein-
stalled in the proper position.

Remove the filters by pushing each filter up
at the angle it is placed in, and rotate down.
Remove the center filter first. Then take out
the grease cups placed on the bottom edge
of the hood coinciding with the bottom
edge of the filters. Gloves should be worn
to provide the proper grip when removing
filters.

Detach the rough-in plate/transition
assembly from the hood by removing the
screws from the top and back of the
assembly. Refer to the illustration below.

Framing must be tied together and to
ceiling joists to provide enough structural
strength to support the weight of the
hood and internal blower, if applicable.

If wall framing is not available, wall
anchors must be used.

*

*

*

*

*

*

*

*

5"

(127)

3

1/2

"

(89)

*Dimension is 1

1/2

"

(38)

7

1/2

"

(191)

17

3/4

"

(451)

8"

(203)

5"

(127)

5"

(127)

5"

(127)

3

1/4

"

(83)

11/16

"

(17)

16

5/8

"

(422)

*

*

*

*

*

*

*

*

*Dimension is 2"

(51)

9

1/2

"

(241)

21

1/4

"

(540)

4

1/2

"

(114)

10"

(254)

8

1/2

"

(216)

4

1/2

"

(114)

4

1/2

"

(114)

4

1/2

"

(114)

13/16

"

(21)

20"

(508)

8"

(203)

Mounting holes for low-profile hoods

Mounting holes for 24" (610) hoods

Rough-In

Plate

Shipping

Screws

Transition

Rough-in plate/transition assembly

S T E P 3 : H O O D P R E P A R A T I O N

IMPORTANT NOTE: If a duct cover is to be
used, follow instructions on page 21 before
installing the wall hood. If you are installing a
recirculating kit, refer to instructions included
with the kit before installing the wall hood.

Advertising