3/8” black tube connection from faucet – Watts Radiant WQC4 RO User Manual

Page 11

Advertising
background image

Page 11







3/8” Black Tube Connection from Faucet

Measure the black tube from faucet to the black drain saddle and
make a straight cut through tube.

Remove black plastic nut from drain saddle. Slip black tube
through black nut. Press the plastic insert into the end of the
tube. Insert black tube into the opening in the drain saddle and
hand tighten the black nut, and add 1/4 turn with a wrench.

This is a gravity feed line, if there is any bend or dip in the
tube the rinse water will not fl ow into the drain properly.
Water may back up and come out of the air gap hole in the
back of the faucet base.

The tubing must be as SHORT and STRAIGHT as possible
to the drain saddle, making a downward slope from faucet
to drain saddle to allow for proper drainage.

Step 24

Note:

Note:

Step 23

How To Use the Quick Connect Fittings on the RO Module

To make a connection, the tube is simply pushed into the fi tting.

It is essential that the outside diameter be free of score
marks and that burrs and sharp edges be removed before
inserting into fi tting.

Fitting grips before it seals. Ensure tube is pushed into
the tube stop.

Push the tube into the fi tting, to the tube stop. The collet
(gripper) has stainless steel teeth which hold the tube
fi rmly in position while the O-ring provides a permanent
leak proof seal.

Pull on the tube to check that it is secure. It is a good practice
to test the system prior to leaving site and /or before use.

To disconnect, ensure the system is depressurized before
removing the tube. Push in collect squarely against face
of fi tting. With the collet held in this position, the tube can
be removed. The fi tting can then be reused.

Advertising