Installation

3. Trim wires to 7/16 inch as shown in the adjacent diagram.

Installation (continued)

4. Connect the BLACK wire of the HA14WD switch to the 120V Hot

building wire (the wire leading to the circuit breaker or fuse box,) using a

twist connector (provided.)
note:

Insert wires straight into the twist connector, the twist

clockwise. Make sure all twist connectors are tight. Secure each

twist connector with electrical tape. Verify no bare wire shows

below the wire connector.

5A. For SInGLe poLe AppLICAtIon onLY: Connect the BLUe wire of the HA14WD to the LoAD wire using

a twist connector (provided.)
5B. For 2, 3, and 4 SWItCH, and MULtI-WAY AppLICAtIonS: Connect the BLUe wire of the HA14WD to

the

LoAD wire of the lighting load using a twist connector provided.

note:

An additional wire run may be necessary in multi-switch applications to connect the

HA14WD directly to the lighting load as shown in the wiring diagrams. Consult with a qualified

electrician if you are unsure about any part of the installation.

6. Connect the ground wire from the box to the bare copper wire on the HA14WD switch. If there is no

ground wire, connect the bare copper wire of the HA14WD to the wall box if it is metal. If the wall box is

plastic, connect the bare copper wire to ground as supplied or consult with a qualified electrician.

7A. For SInGLe poLe AppLICAtIon onLY: Remove the semi-stripped end of the reD wire and apply the

twist connector to this wire without any connecting wire.
7B. For 2, 3, and 4 SWItCH, and MULtI-WAY AppLICAtIonS: Connect the reD wire to the COMMON

wire (aka traveler) of the next switch in the circuit.

8. Tuck wires into wall box leaving room for the HA14WD unit. For testing purposes, partially screw

mounting screws (provided) of the HA14WD into the wall box.

9. Restore electrical power to the circuit.

note:

Before operating the switch, be sure the air-gap switch (small

slide switch located below the rocker switch) is in the ON position.

The switch is in the ON position if the vertical line (ON symbol) is

visible to the right of the air-gap switch.

note:

When changing a light bulb, slide the air-gap switch to the

OFF position. The OFF position is indicated if there is an “O” (OFF

symbol) visible to the left of the air-gap switch. This disconnects

electrical power to the light fixture to prevent an electrical shock.

When the bulb has been replaced, slide the switch back to the ON

position.