Wolf ICBCT30EU User Manual

Page 11

Advertising
background image

11

I N S TA L L AT I O N

I N S T R U C T I O N S

M U LT I P L E C O O K T O P

I N S T A L L A T I O N

If the framed electric cooktop is to be used
with any combination of additional cooktop
units or modules with a filler strip, the cut-out
width is calculated by adding the correspon-
ding units' cut-out dimensions plus 32 mm for
each additional unit. Refer to the illustration
below.

IMPORTANT NOTE: For Model ICBCT15E,
the cut-out width should be increased from
340 mm to 356 mm when installed with
multiple units.

IMPORTANT NOTE: Unframed electric
cooktops Models ICBCT30EU and ICBCT36EU
are not designed to be installed in combination
with other cooktop units.

IMPORTANT NOTE: When multiple units are
installed side by side, each unit must have its
own separate recommended electrical circuit.

64 mm

min

FRONT OF COUNTERTOP

489 mm

CUT-OUT

DEPTH

743 mm

TWO MODULES WIDTH

1130 mm

– THREE MODULES WIDTH OR

1124 mm

– 762 mm COOKTOP AND ONE MODULE

1518 mm

– FOUR MODULES WIDTH OR

1511 mm

– 762 mm COOKTOP AND TWO MODULES OR

1276 mm

– 914 mm COOKTOP AND ONE MODULE

356 mm

CUT-OUT

WIDTH

Countertop cut-out dimensions for installation of multiple cooktops

A C C E S S O R I E S

Optional acces-
sories are available
through your
Wolf dealer. To
obtain local dealer
information, visit
our website,
wolfappliance.com.

When two or more modules are installed
together, an integrated module filler strip
(IFILLER/S) is recommended. If a 762 mm
downdraft ventilation system is also installed,
an integrated module support for downdraft
ventilation (ISUPPORT) is also required.
Contact your Wolf dealer for information on
these accessory components.