Westinghouse W-147 User Manual

Page 4

Advertising
background image

4

NOTE: Underwriters Laboratories (UL) does not require all fixtures to have ground wires. These
fixtures meet all UL specifications.

1. Turn

off power at circuit box to avoid possible electric shock.

2. Secure mounting bar (A) to outlet box (B) with outlet box screws (C) (not included) (see fig. 1).
3. Thread hex nut 1 (D1) onto mounting nipple (E) approximately 1/4 inch and insert lock

washer (F), then thread mounting nipple (E) onto mounting bar (A) and secure hex nut 1 (D1).

4. Place glass shade (G) inside fixture ring (H).
5. Slide fixture arms (I), threaded end first, up through openings in fixture ring (H).
6. Thread metal washer (J) and hex nut 2 (D2) onto each fixture arm (I), then insert fixture

arms (I) into side openings of cap (K) and secure each by inserting a cotter pin (L) through
opening in end of fixture arm (I).

7. Open one link on bottom end of chain (M). Attach to fixture loop (N). Securely close link on

chain (M).

8. Thread screw collar ring (O) onto screw collar (P), then place canopy (Q) over top of screw

collar (P).

9. Lace wires up through every other link on chain (M) then through screw collar (P) and

mounting nipple (E).

10. Open one link on top end of chain (M). Attach to loop on screw collar (P). Securely close

link on chain (M).

11. Identify color coding of fixture wires (see fig. 2).
12. To connect wires, take black fixture wire (group A from fig. 2) and place evenly against

black outlet box wire. Do not twist wires.

13. Fit wire connector (R from fig. 1) over wires and twist until there is a firm connection. If

wire connector (R) easily comes off, reattach and check again for a firm connection.

14. Repeat steps 12 and 13 with the white (group B from fig. 2) fixture wires and outlet box wires.

15. Partially thread green grounding screw (S) into side hole (T) on mounting bar (A) (see fig. 1).

16. Wrap ground wire from fixture around green grounding screw (S) leaving enough excess

wire to then connect ground wire and outlet box wire with wire connector (R), if applicable.

17. Tighten green grounding screw (S). Do not over tighten.
18. Remove screw collar ring (O) from screw collar (P) and secure screw collar (P) to mounting

nipple (E).

19. Tuck wires inside outlet box (B).

20. Raise canopy (Q) to ceiling and secure screw collar ring (O) to screw collar (P).

MOUNTING AND WIRING INSTRUCTIONS

FIXTURE ASSEMBLY INSTRUCTIONS

Warning: This fixture is for indoor use only.

1. Install lamp(s). Do not exceed recommended wattage.

2. Turn power back on at circuit box.