ASSEMBLY / GAS INSTRUCTIONS

13

12

IMPORTANT LP CYLINDER INFORMATION

Failure to follow these DANGER statements exactly may result in a fi re
causing death or serious injury.

ƽ DANGER

ƽ NEVER store a spare LP Cylinder near this fi replace.

ƽ NEVER fi ll the tank beyond 80% full.

Your Weber

®

gas fi replace is equipped for a cylinder supply system

designed for vapor withdrawal.

ƽ WARNING: Only use this fi replace outdoors in a well-

ventilated area. Do not use in a garage, building,
breezeway or any other enclosed area.

The proper fi lling methods for the fi lling of your cylinder are by weight or
volume, as described in NFPA 58. Please make sure your fi lling station fi lls
your LP cylinder by weight or volume. Ask your fi lling station to read purging
and fi lling instructions on the LP cylinder before attempting to fi ll.

CHECK THAT THE BURNER VALVE IS OFF

Valve is shipped in the OFF position, but you should check to be sure that
it is turned OFF. Check by pushing down and turning clockwise. If it does
not turn, it is off. Proceed to the next step. If it does turn continue turning it
clockwise until it stops, then it is off. Proceed to the next step.

ƽ DANGER

Do not operate fi replace until ALL rain shields have
been removed. Failure to do so could result in a
fi re or explosion which can cause serious bodily
injury or death, and damage to property.

14

Always attach rain shields when not in
use and for storage.