Installation 8, Installation diagram available on next page – Windster RA-77 User Manual

Page 9

Advertising
background image

INSTALLATION

8

3. COLD WEATHER INSTALLATION (OPTIONAL)

a. Check with your local building codes to see if a CFM reducer is an

acceptable alternative to make-up air.

b. Remove the RA14LCFMR (CFM reducer) and inspect for any sign of

defect or damage. (ie. Cracks, broken flips)

c. AFTER COMPLETING Step A

– G of Section 1 WALL MOUNT

INSTALLATION

d. Place the CFM reducer onto the outlet of the unit and seal the connection

point with aluminum tape. (Be sure it is secure with no opening or gaps)

e.

REPEAT “STEP F – M” from WALL MOUNT INSTALLATION section.

4. DUCTLESS INSTALLATION (OPTIONAL)

a. AFTER COMPLETING Step A

– G of Section 1 WALL MOUNT

INSTALLATION

b. Remove the RA14LDK (ductless kit) and inspect for any sign of defect or

damage. (ie. dents, broken inlet)

c.

Mount the ductless kit at the top of the ceiling using the screws provided.

d. Make sure the duct cover vent opening aligns with the air diverter. (Fig.

2e)

e.

Connect a 6” or 7” ducting to the collar of the hood.

f.

Connect the exhaust pipe to the outlet of the unit. (Fig. 2b)

g. Connect the exhaust pipe to the air diverter collar.

h. REPEAT

“STEP K – M” from WALL MOUNT INSTALLATION section.

Installation diagram available on next page