3

NOTE

NOTE

Relay contacts shown are thermostatically operated.

The following wiring diagrams show typical terminal identifica-
tion and wiring. For proper installation, refer to the original
manufacturer's instructions.

L

R

E

24 VAC

120 VAC

Hot

MALF

FAN ON

EMERGENCY

SYSTEM

MONITOR

SWITCH

FAN

AUTO

Heat

or Cool

FAN

AUTO

Emer

Neutral

THERMOSTAT

SYSTEM

G

W2

Figure 3. Typical wiring diagram for single transformer systems

TRANSFORMER

Changeover

Relay*

C

Y

O/B

Compressor

Contactor

* Changeover Relay is energized in COOL when O/B switch is in the “O” position

Changeover Relay is energized in HEAT when O/B switch is in the “B” position

Aux/Emer

Relay

(Stage 2)

Fan

Relay

Thermostat

Control

Circuit

Emergency

Relay

L

R

E

24 VAC

120 VAC

Hot

MALF

FAN ON

SYSTEM

MONITOR

SWITCH

FAN

AUTO

Heat

or Cool

FAN

AUTO

Emer

Neutral

THERMOSTAT

SYSTEM

G

W2

Figure 4. Typical wiring diagram for two transformer systems with NO safety circuits

TRANSFORMER

Changeover

Relay*

C

Y

O/B

Compressor

Contactor

* Changeover Relay is energized in COOL when O/B switch is in the “O” position

Changeover Relay is energized in HEAT when O/B switch is in the “B” position

Aux/Emer

Relay

(Stage 2)

Fan

Relay

Thermostat

Control

Circuit

Emergency

Relay

Limit or

Safety

Switches

TWO COMMONS MUST
BE JUMPERED TOGETHER!

HOT

NEUTRAL

120 VAC

24 VAC

CUT AND

TAPE OFF!

If safety circuits are in
only one of the systems,
remove the transformer
of the system with NO
safety circuits.

NOTE

EMERGENCY

L

R

E

MALF

FAN ON

SYSTEM

MONITOR

SWITCH

FAN

AUTO

Heat

or Cool

FAN

AUTO

Emer

G

W2

Figure 5. Typical wiring diagram for two transformer systems with safety circuits in BOTH systems

Changeover

Relay*

C

Y

O/B

Compressor

Contactor

* Changeover Relay is energized in COOL when O/B switch is in the “O” position

Changeover Relay is energized in HEAT when O/B switch is in the “B” position

Aux/Emer

Relay

(Stage 2)

Fan

Relay

Thermostat

Control

Circuit

Emergency

Relay

TWO COMMONS MUST
BE JUMPERED TOGETHER!

24 VAC

120 VAC

HOT

NEUTRAL

THERMOSTAT

SYSTEM

HOT

NEUTRAL

120 VAC

Limit or

Safety

Switches

Limit or

Safety

Switches

Limit or

Safety

Switches

24 VAC

Limit or

Safety

Switches

COMMON

COMMON

Auxiliary

Heating

Transformer

Heat Pump Transformer

24 VAC

ACCESSORY

RELAY N.O.

CONTACT

Polarity must be observed. If the HOT side of
the second transformer is jumpered to the
COMMON side of the first transformer a short
will be made. Damage to equipment will occur
when power is restored.

NOTE

The accessory relay scheme
is required when safety
circuits exist in both systems.

NOTE

EMERGENCY