AQUA PLUS

indirect

-

fired

water

heaters

— Product Manual

Boiler-side piping

(continued)

Figure 12

Multiple water heaters — domestic water piping

Figure 13

Alternate methods of revers-return piping and Easy-Fit® Manifold detail

Failure to install automatic

mixing valve where recom-

mended can result in severe

personal injury or death.

1. This drawing is conceptual

only. It shows representa-
tive piping components
and layout. Weil-McLain
does not represent that this
drawing meets any partic-
ular mechanical or build-
ing codes. The installer is
responsible for inclusion
of all required safety de-
vices, or other miscella-
neous piping hardware not
shown on drawing. The
installer is responsible for
proper sizing / selection of
all hardware shown on this
diagram.

2. Wire water heater thermo-

stats in series when con-
necting to boiler controller
or boiler T-T terminals.

3. Install automatic mixing

valve at either the system
hot water connection or
at each water heater.

4. See page 8 through page 10

for additional recircula-
tion information and pip-
ing details.