Specifications

Power Bases
• Single phase, (2 SCRs)
• 3 phase, 2 leg control, (4 SCRs)

Resistive load only, zero cross firing only

• 3 phase, 3 leg control, (6 SCRs)
• 3 phase, 3 leg control, (6 SCRs) for 4-wire wye loads
• Multizone, two and three single-phase zones
Output Control Options
• Zero cross contactor, V

Î

(dc) input

• Zero cross control, fixed time base

• Time base one or four seconds with digital programmer

• Zero cross control, variable time base
• Phase angle control and phase angle control with current limit

(not for 3-phase, 2-leg models)
• Soft start factory default four seconds upon power-up, and

adjustable from 0.0 to 120 seconds

• Soft start upon input signal change, output rate of change

adjustable to limit max rate of change from 0.1 to 100 percent
per 0.1 second. Factory default 10 percent

• Current transformer included when required
• Line voltage compensated (variable time base and phase angle

controllers only)

• Standby or non-operational mode
Output Voltage and Current Rating
• 24 to 120V

Å

(ac) (+10 percent, -15 percent)

• 200 to 480V

Å

(ac) (+10 percent, -15 percent)

• 200 to 600V

Å

(ac) (+10 percent, -15 percent)

• 65 through 250 amps per pole, model dependent; see Output

Amperage Chart and Rating Curves

• Minimum load 1 amp rms ac
• Maximum leakage current 5mA
Alarms
• Single alarm relay
• Latching or non-latching
• Separate high and low values
• Alarm silencing (inhibit) on po wer up for alarm
• Alarm indication LEDs, shorted SCR, open heater, fuse
• Electromechanical relay, form C contact, software

configurable
• Minimum load current 10mA @ 5V

Î

(dc)

• Rated resistive loads: 3 amps @ 250V

Å

(ac) or 30V

Î

(dc)

max., inductive load rating 1.5 amps with a power factor

0.4 without contact suppression

Heater Bakeout
• For single-phase (phase to neutral) and 3-phase 6 SCR

models only (not for 3-phase, 2-leg models)

• Soft start with over current trip, runs until programmed bakeout

time expires, then goes burst or phase angle firing. Factory
default of 24 hours

• Adjustable 0 - 9999 minutes with over current trip
• Internal current transformer included
Command Signal Input
Analog
• Field selectable linear voltage and current of low and high

points within 0-20mA and 0-10V

Î

(dc)

• Manual control input through front panel
• Factory default 4-20mA input
• Voltage input impedance 11k

W

nominal

• Current input impedance 100

W

nominal

Digital
• On-board digital programmer/display and optional serial

communications

Retransmit
• Field selectable and scalable within 0-20mA,

800

W

maximum or 0-10V

Î

(dc), load, 1K

W

minimum load.

The default is 4-20mA

• Resolution:

mA ranges = ±5µA
V

Î

(dc) = ranges 2.5mV nominal

• Calibration accuracy:

mA ranges = ±20µA
V

Î

(dc) ranges = 10mV nominal

• Temperature stability: 100ppm°C
Digital Programmer/Display and Communications
Capabilities
• Programming functions

• Adjust input and output control type, alarms and soft start,

heater bakeout and current limit prompts

• Monitoring functions

• Display input and output values along with actual

output current

• Data retention of digital prog rammer/display upon power failure

via nonvolatile memory

Serial Communications
• RS-232 for single drop control
• EIA-485 for single or multidrop control

• 32 units maximum can be connected.With additional

485 repeater hardware, up to 247 units may be connected

• Isolated
• Modbus

RTU protocol

• 1200, 2400, 4800, 9600, 19200 baud rates
Controller Power Supply
• Universal line voltage input range 100 to 240V

Å

(ac)

(+10 percent, -15 percent) at 55VA max

• 50/60Hz ± 5 percent line frequency independent
• Controller line voltage for electronic power supply can be run

on separate line voltage

Natural Convection and Fan Cooled Models
• Cabinet venting may be required
• See Amperage chart on the back page for all models.
Power Dissipation (Watts)
• Approximately 1.25 watts/amp per controlled leg
Isolation
• Command signal to load and line/load to ground

2200V

Å

(ac) minimum

• On-board semiconductor fuses provide SCR protection
Mounting
• Mounts on a removable subplate
• Heat sink fins must be mounted in vertical orientation
High Current Terminals
• Touch safe
• 10 mm (

3

8

in.) Allen head compression terminals will accept

#6 AWG to 350 MCM wire. Allen wrench adapter (included) for
10 mm (

3

8

in.) socket, 6 point only

• Torque to 180 in.-lbs (20.3 Nm)
• Wire strip to 30 mm (1

1

8

in.)

Controller Terminals
• Touch safe
• 2.5 mm (

1

8

in.) blade screwdriver, accepts 12-22 AWG or

2 No. 22-18 AWG wires

• Torque to 8 in.-lbs (0.9 Nm)
• Wire strip to 6 mm (0.24 in.)
Operating Environment
• 50°C (122°F) base rating

• 0 to 60°C (32 to 140°F) fan cooled
• 0 to 65°C (32 to 149°F) natural convection cooled

• 0 to 90 percent RH, non-condensing
• Meets EN50178, Pollution degree three
Storage Temperature
• -40 to 85°C (-40 to 185°F)
Shipping Weight
• 10.3 kg (23 lbs)
Agency Approvals
• UL

®

508 listed, File #E73741, Vol. three, Sec.two

• C-UL

®

listed to C22.2 NO. 14

• VDE EN 50178 License 115054
• CE 89/336/EEC (EN61326), Class A with filter,

CE 73/23/EEC (EN50178)