Troubleshooting – Wagner SprayTech CS9100 User Manual

Page 20

Advertising
background image

18

Problom

Sprayer does not startup

Sprayer starts up but
does not draw up paint

Sprayer draws up paint
but pressure does not
build up

Cause

TROUBLESHOOTING

Provided you have followed the instructions, the sprayer will operate efficiently and give trouble-free service. Should any
unexpected problem arise you can, in most cases, remedy the problem by following the chart below.

Remedy

1. Plug in
2. Replace fuse
3. Test power supply voltage

4. Replace switch
5. Replace with 3-prong cord. Any extension cord

used must be 3-wire, 12 gauge minimum, with a 3-
wire plug that will plug into a 3-wire electrical outlet.

6. Repair or replace. Take to SprayTECH Authorized

Service Center.

1. Add more paint or immerse suction tube in paint

2. Clean or replace filter
3. Clean connection and tighten firmly

4. Replace tube

5. Take valve off and clean it

6. Fill only with hydraulic oil part number 0088009

(quart) or 0088010 (gallon). Caution: do not
overfill

7. Push Inlet Valve Plunger to free stuck valve
8. Replace inlet valve

9. Push Outlet Valve Plunger to free stuck valve

10. Clean hydraulic housing if needed (blown dia-

phragm may cause internal freezeup). Replace
defective diaphragm parts or tighten nut if loose

11. Replace tube

12. Replace piston. If cylinder is scored, replace

hydraulic housing

13. Use only hydraulic oil part number 0088009

(quart) or 0088010 (gallon). Change initial fill after
first 20 hours of operation. Change every 200
hours there after. Bleed after changing

14. Remove fan cover and straighten

1. Replace valve

2. Fill to appropriate level using only hydraulic oil part

number 0088009 (quart) or 0088010 (gallon)

3. Clean hydraulic housing if needed. Replace

defective diaphragm parts or tighten nut if loose

4. Dismantle valve. Clean or replace valve spring first.

If this does not work, replace ball

5. Replace tube
6. If piston is scored, replace piston. If cylinder is

scored, replace hydraulic housing

7. Replace housing

1. Sprayer not plugged in
2. Blown fuse in circuit
3. No voltage or low voltage at

wall plug

4. Bad sprayer ON-OFF switch
5. Damaged cord or extension

cord, or cord capacity too low

6. Defective motor

1. No paint or suction tube not

totally immersed in paint

2. Suction filter clogged
3. Suction tube loose at inlet

valve

4. Suction tube damaged or de-

fective

5. Priming valve plugged
6. Hydraulic oil level very low or

empty

7. Inlet valve stuck
8. Inlet valve damaged (paint is

drawn up and leaks through
inlet valve)

9. Outlet valve stuck
10.

Diaphragm membrane
ruptured, broken diaphragm
spring, cracked diaphragm
disk, or loose diaphragm nut

11.

Loose oil suction tube in hy-
draulic housing

12.

Scored piston or cylinder

13.

Wrong grade of hydraulic oil, or
using fluid other than hydraulic
oil

14.

Rear motor fan cover bent

1. Priming valve defective (paint

runs back via return hose)

2. Hydraulic oil level low

3. Diaphragm membrane

ruptured, cracked diaphragm
disk, broken diaphragm spring,
or loose diaphragm nut

4. Outlet valve stuck, dirty, or has

worn parts

5. Defective suction tube
6. Scored piston or cylinder

7. Cracked hydraulic housing or

paint pump housing

Advertising