Whirlpool GGE350LW User Manual

Freestanding electric range with double ovens

Advertising
background image

Freestanding Electric Range with Double Ovens

PRODUCT MODEL NUMBERS

PRODUCT DIMENSIONS

GGE350LW

Because Whirlpool Corporation policy includes a continuous commitment to improve our
products, we reserve the right to change materials and specifications without notice.

Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.

Electrical:

To properly install your range, you must determine the type

of electrical connection you will be using and follow the instructions
provided for it here.

Range must be connected to the proper electrical voltage and frequency
as specified on the model/serial number rating label. The model/serial
number rating label is located on the bottom right front of the toe kick
plate. Refer to the figures in the “Product Dimensions” section of the
“Location Requirements” section.

This range is manufactured with the neutral terminal connected to the
cabinet. Use a 3-wire, UL listed, 40- or 50-amp power supply cord
(pigtail) (see following Range Rating chart). If local codes do not permit
ground through the neutral, use a 4-wire power supply cord rated at
250 volts, 40 or 50 amps and investigated for use with ranges.

Range Rating*

Specified Rating of
Power Supply Cord Kit
and Circuit Protection

120/240 Volts

120/208 Volts

Amps

8.8 - 16.5 KW

7.8 - 12.5 KW

40 or 50**

16.6 - 22.5 KW

12.6 - 18.5 KW

50

*The NEC calculated load is less than the total connected load listed on

the model/serial rating label.

**If connecting to a 50-amp circuit, use a 50-amp rated cord with

kit. For 50-amp rated cord kits, use kits that specify use with a

nominal 1

³⁄₈" (34.9 mm) diameter connection opening.

A circuit breaker is recommended.

CABINET OPENING DIMENSIONS

IMPORTANT: If installing a range hood or microwave hood
combination above the range, follow the range hood or
microwave hood combination installation instructions for
dimensional clearances above the cooktop surface.

A freestanding range may be installed next to combustible
walls with zero clearance.

*NOTE: 24" (61.0 cm) minimum when bottom of wood or

metal cabinet is covered by not less than 1⁄4" (0.64 cm)
flame retardant millboard covered with not less than No. 28
MSG sheet steel, 0.015" (0.4 mm) stainless steel, 0.024"
(0.6 mm) aluminum or 0.020" (0.5 mm) copper.

30" (76.2 cm) minimum clearance between the top of the
cooking platform and the bottom of an uncovered wood or
metal cabinet.

Cabinet opening dimensions shown are for 25"
(64.0 cm) countertop depth, 24" (61.0 cm) base
cabinet depth and 36" (91.4 cm) countertop height.

Ref. W10270322A

8/28/09

®

*Excludes handle. Dimension given is from wall to front of oven

door and will vary based on electric outlet receptacle installation.

A.

" (119.9 cm)

B. Model/serial number rating

label (located on bottom right
front of the toe kick plate)

C.

" (91.4 cm)

D. 29 " (75.9 cm)

E. 26

A

E*

D

C

B

46

35

27¼" (66.8 - 69.2 cm)*

⁷⁄₈

⁷⁄₈

⁷⁄₈

⁵⁄₁₆

A. 13" (33 cm) upper cabinet

depth

B. 30" (76.2 cm) min. opening

width

C. For minimum clearance to the

top of the cooktop, see NOTE.

D. 30" (76.2 cm) min. opening

width

E. Cabinet door or hinge should

not extend into cutout.

F. 3-wire shaded area -

7" (17.8 cm) min. from left side

from floor, 6" (15.2 cm) max.
width*

G. 4-wire shaded area -

10" (25.4 cm) min. from right

max. from floor, 6" (15.2 cm)
max. width*

using a flush mount outlet.

(3.8 cm) from wall or ran

ge will not slide all the way back.

A

B

D

F

E

C

G

H

cabinet, 5¾" (14.6 cm) max.

side cabinet, 5¾" (14.6 cm)

H.

1½" (3.8 cm) min. from floor if

*Nothing located in shaded areas can extend more than 1½"