Whynter RESIDENTIAL PORTABLE DEHUMIDIER RPD-651W User Manual

Page 5

Advertising
background image

5 |

P a g e



Do not, under any

circumstances, cut,

remove, or bypass

the grounding prong.






This unit is grounded through the

power cord plug when plugged

into a matching wall outlet.

Electrical Information

The appliance is equipped with a three-prong grounded plug

on the power cord for your protection. Never modify,
remove or attempt to repair the plug yourself.

Do not pull the unit by the power cord or pull on the cord to

unplug the unit. Grip the plug and pull it away from the wall
receptacle.

Ensure the power cord is not tangled, knotted or otherwise

distorted before operating the unit.

The dehumidifier must be plugged directly into a properly

grounded wall outlet receptacle. If the wall receptacle you
intend to use is not adequately grounded or protected by a
time delay fuse or circuit breaker, have a qualified
electrician install an outlet that is appropriate to local
electrical codes and requirements.

Do not use extension cords, power strips or an adapter plug

with this unit

Always unplug the unit before opening, installing or servicing.

How it Works

When the dehumidifier is started, the fan begins to pull moisture-laden air across the dehumidifying
coils. The coils condense or draw moisture from the air, and air flows through the side louvers into the
room as dry, warm air. Moisture removed from air is collected in a water bucket on the front of the
dehumidifier.
The unit is designed to operate between 41°F (5°C), and 96°F (35°C). The "Compressor" circuit has
an automatic 3 minute time delayed start if the unit is turned off and on quickly. This prevents
overheating of the compressor and possible circuit breaker tripping. Make sure the tank is fitted
correctly otherwise unit will not turn on.

Energy Saving Guide

This Whynter dehumidifier is an Energy Star rated appliance. Follow the guide below can help to get
the best performance and efficiency from your dehumidifier.

Do not cover the air intake and outlet.

Do not place the unit in front of curtains or drapes - to ensure they do not obstruct the air
intake.

Keep curtains, blinds or drapes closed during the sunniest part of the day.

Close all windows and doors.

Indoor relative humidity should ideally be kept between 35%RH and 60%RH depending on the
ambient temperature.

Make sure the unit is on a hard and level surf ace.

To prolong the compressor's life, please wait at least 3 minutes before turning the unit back on
after shutting it off.

Inspect and keep the air filter clean by cleaning regularly.

Perform routine maintenance.





Advertising