Caution – White Rodgers 1F97W-51 User Manual

Page 13

Advertising
background image

13

CAUTION

!

HOLD TEMPERATURE — The thermostat

can hold any temperature within its range
for an indefinite period, without reverting to

the program. Press

HOLD
COPY

. HOLD will be

displayed. Then choose the desired hold
temperature by pressing

or

. The

thermostat will hold the room temperature

at the selected setting until you press

RUN

PRGM

to start program operation again. This fea-
ture is ideal for energy conservation when
the building is unoccupied for an extended
period of time.

°

F/

°

C CONVERTIBILITY — Press

TIME
FWD

and

TIME

BACK

at the same time until the tem-

perature display is in

°

C (Celsius). To dis-

play

°

F, repeat the process.

ADJUSTABLE HEATING AND COOLING

CYCLE TIMES (ANTICIPATION) — If the
heating/cooling system is turning on and off
too often (short cycles) or not often enough
(long cycles), you may want to adjust the
anticipation setting.

A cooling anticipation setting of less than
10 may cause decreased compressor life.

To adjust heat anticipation, press

SET

CLOCK

and

ADV
DAY

at the same time. The display will

show HEAT 5 (this is the factory prepro-
grammed heating anticipation setting). You
may select any heat anticipation setting
from 2 to 40 (note that for hydronic sys-
tems, a minimum anticipation setting of
15 is recommended
).

Advertising