If the pump does not operate after
repeated attempts, check the following:

1. Vertical distance of pump to water

level must not be over 25 feet.

2. Suction piping must be air tight.

3. Be sure valve(s) are open if used in

discharge or suction piping.

Never run the

pump with a closed

or clogged discharge. The water inside
the pump could boil and damage the
pump.

Maintenance

Maintain adequate ventilation for the
pump motor. The motor bearings are
permanently lubricated at the factory.
Additional lubrication is not required.

DRAINING FOR WINTER
Always protect pump and piping
against freezing temperatures. If there
is any danger of freezing, drain the
system. To drain the system:

1. Remove the pipe plug from the

discharge tee.

2. Remove the 1/4” plug from the

lower front face of the pump.

3. Drain all piping below the frost line.

3

Operating Instructions and Parts Manual

pump in accordance with the National
Electrical code and all applicable local
electrical codes.

The motor must be grounded by
connecting a copper conductor to the
grounding screw provided within the
wiring compartment.

The voltage of power supply must match
the voltage of the pump. The WLS75,
WLS100 and WLS150 have dual voltage
motors preset at the factory to 230 volts.
The motors can be converted to 115 volts
by turning the voltage selector to the
desired voltage (See Figure 5). Use a
needle nose pliers to pull the selector out
approximately 1/4”, rotate and then
reinsert in correct position. The WLS200
cannot be converted; the motor is
230 volts only
.

CONNECTING WIRES

Terminal cover must be in place for safe
operation. Ground in accordance with local
and national electrical codes. Keep fingers
and objects away from openings and
rotating parts. Disconnect power sources
before touching internal parts. See figure 6
for appropriate wiring locations.

Operation

Never run the

pump dry. Running

pump without water may cause seal
damage. Fill the pump with water
before starting.

PRIMING THE PUMP

After pump installation is complete, the
pump must be primed. Remove the
pipe plug in the discharge piping and
fill the pump and suction pipe with
clean water. Turn power to pump on. If
the pump does not pump water in 10
minutes, turn off the pump and refill
with clean water.

115 V

230 V

115 V

230 V

Figure 5 - Voltage Selector

Electrical Connections

(Continued)

Lift

in

Feet

3/4 HP Pump Capacity in

GPH Operating Pressure (psi)

10

20

30

5

3900

3320

2320

10

3780

3120

2100

15

3600

2910

1190

20

3250

2670

990

25

3010

2560

840

Lift

in

Feet

1-1/2 HP Pump Capacity in

GPH Operating Pressure (psi)

10

20

30

40

5

4790

4480

3480

2060

10

4610

4310

3190

1520

15

4320

4040

2900

0

20

3900

3720

2680

0

25

3810

3300

2390

0

Lift

in

Feet

2 HP Pump Capacity in GPH

Operating Pressure (psi)

10

20

30

40

5

5980

5560

4310

3060

10

5410

5220

4090

2880

15

5230

4980

3900

2570

20

4120

3840

3510

2210

25

3980

3600

3300

0

Lift

in

Feet

1 HP Pump Capacity in GPH

Operating Pressure (psi)

10

20

30

5

4410

3920

2570

10

4180

3520

2300

15

3830

3340

1780

20

3680

3060

1160

25

3340

2720

1260

www.waynepumps.com

WLS75, WLS100

WLS150, WLS200

Figure 6 - Connecting Wire

Ground Screw

Ungrounded

Line (L1)

Terminal

Board (L2)