7

1

1

3

2

CONDUIT

FLOOR

DUCT

AIR CLEANER

MAINTENANCE

For maximum efficiency, your air filter should be in-
spected once a month and changed if dirt loading is
heavy. When changing is required, the following proce-
dure should be used:

!

CAUTION

The fiber filter used in this compartment for air
cleaning must be replaced every 90 days. Your
heating and cooling efficiency will decrease due
to insufficient air flow when filter becomes dirty.

1.

Remove door from air filter compartment by unscrew-
ing the knob.

2.

Remove 5

filter and throw away.

3.

Replace 5

filter by sliding it into the compartment.

(Note direction of air flow.)

4.

Replace door.

When ordering repair parts, always give the following
information as shown in this list.

1. The PART NUMBER
2. The PART DESCRIPTION
3. The MODEL NUMBER of the Air Filter Compart-
ment

Always order by “PART NUMBER” . . .
Not by “ITEM NUMBER”

PARTS LIST FOR

AIR FILTER COMPARTMENT

REPAIR and UPGRADE PARTS

Vertical
Section

Wood Block

Tape All

Joints

Part Number

Item

No.

Description

1000

1400

1600

2000

1

Compartment & Door

ACB1000

ACB1400

ACB1600

ACB2000

2

Filters 5”

FR1000

FR1400

FR1600

FR2000

3

Screw, Fastener

F870-0026 F870-0026 F870-0026 F870-0026

Figure 15

Figure 16

Description

1000

1400

1600

2000

Electronic Air Cleaner Retrofit Kit ACR1000

ACR1400

ACR1600

ACR2000

ELECTRONIC AIR CLEANER KIT