White Rodgers 1F92-71 User Manual

Page 30

Advertising
background image

30

want to stop programming at this point,

press

RUN

PRGM

to start the normal program

function. See PROGRAMMING YOUR
THERMOSTAT
.

4.

What happens if the electricity goes off
or is manually shut off?

If you have not installed a 9 volt alkaline
battery, the display will go blank and the
program will be lost in approximately one
minute. When electricity is restored, the
thermostat will maintain a heating tem-
perature of 64

°

F and a cooling tempera-

ture of 82

°

F until you reenter your pro-

gram. Setpoint temperature will not be
displayed.

If a fresh 9 volt Energizer

®

alkaline battery

is installed, the program will be maintained

for about one week with no 24 VAC power
present to the thermostat. See OPERAT-
ING YOUR THERMOSTAT
.

5.

Why can’t I program the thermostat in
the AUTO mode?

The thermostat can only be programmed
in the HEAT and COOL modes. See PRO-
GRAMMING YOUR THERMOSTAT
.

6.

What can cause the thermostat display
to freeze or go blank?

A completely blank display may indicate
that power has been lost to the thermostat
and the backup battery is also dead. How-
ever, if there is power to the thermostat
and the display is blank or frozen, static
discharge is probably the cause.