1. First hour rating based on heating water from 50°F to 140°/115°F with 180°F boiler water temperature. Gas- and oil-fired

and electric water heater first hour ratings based on DOE test procedure using 90°F temperature rise (55°F to 145°F).

2. Net I=B=R Output, Water
3. Useable hot water based on recent completion of recovery period, but no additional boiler input after draw begins.

Table 1: Peerless Partner Ratings

2

d. Boiler. PP-80, PP-120, PP-80-DW, and PP-120-DW require full boiler output listed in Table 1. If boiler is a

Category IV condensing boiler, such as Peerless

®

Pinnacle

®

, the above Peerless

®

Partner

®

models can be

used with reduced boiler output. If boiler output is less than shown in Table 1 reduce first hour rating as
shown in Table 2. Increase boiler size only if first hour rating does not meet estimated peak hour usage.

If a boiler with listed output is not needed for space heating, an alternative to a PP-80/120 would be
a PP-40 or PP-60 piped in series with an unfired storage tank (i.e. electric water heater without heating
elements energized).

If Peerless Partner is to be used with Peerless Boilers Series 63 or Series 64 steam boiler, refer to Series
63/64 Installation, Operation and Maintenance Manual for special installation and operation instructions.
PB Heat, LLC cannot recommend the use of other steam boilers with Peerless Partner at this time. Other
than Series 63 and Series 64 steam boilers, Peerless Partner should only be used with water boilers.
Contact PB Heat, LLC for additional information.

e. Domestic water priority. First hour ratings may be less than published when boiler output is shared with

space heating. Generally a consumer will notice a drop in domestic water temperature before a drop in
space heating temperature. Giving domestic water production priority by directing entire boiler output to
Peerless Partner will maximize domestic water output. However, prioritization controls could result in an
unacceptable drop in space heating temperature when large quantities of domestic hot water are used,
and a prioritization control malfunction could result in loss of space heating.

3. Multiple Water Heaters. Peak domestic water usage (first hour rating) or unusual peak draw may not be met

with a single water heater. Multiple units can be installed as either a bank of tanks acting as a single unit, or
as multiple individual units sized and located for specific draw situations.

Model

No.

First Hour Rating

1

[gallons]

Minimum Boiler Output

2

to Achieve

First Hour Rating [Btu per hour]

Useable Hot Water

[U.S. Gallons]

3

Heat Exchanger

Surface Area [ft

2

]

140°F

115°F

PP-30-LB

169

234

114,000

22

15

PP-40

212

292

141,000

28

20

PP-60

266

370

174,000

46

20

PP-80

330

440

212,000

64

34

PP-120

423

564

269,000

94

34

PP-40-DW

110

152

115,000

28

20

PP-60-DW

126

174

188,000

46

20

PP-80-DW

160

221

220,000

64

20

PP-120-DW

296

414

252,000

94

20