Electrical schematic, Accessories, Liquid shield plus – Wagner SprayTech 840i User Manual

Page 23: Piston lube, Miscellaneous, Airless tip selection

Advertising
background image

© Titan Tool Inc. All rights reserved.

23

The following chart indicates the most common sizes and the
appropriate materials to be sprayed.

Fan widths measuring 8" to 12" (20 to 30 cm) are preferred
because they offer more control while spraying and are less
likely to plug.

Liquid Shield Plus

Cleans and protects spray systems
against rust, corrosion and premature
wear.

Part No.

Description

314-483 ...........4 ounce bottle
314-482 ...........1 quart bottle

Piston Lube

Specially formulated to prevent materials
from adhering to the piston rod, which
becomes abrasive to the upper seals.
Piston Lube will break down any material
that may accumulate in the oil cup and
keep it from drying.

Part No.

Description

314-481 ...........4 ounce bottle
314-480 ...........8 ounce bottle

Miscellaneous

Part No.

Description

490-012 ...........Hose coupling, 1/4" x 1/4"
730-397 ...........High pressure fluid Gauge
314-171 ...........Lubriplate, 14 ounce individual
314-172 ...........Lubriplate, 6 lb. can

700-1037 ..........Electrostatic discharge (ESD) wrist strap

700-897 ...........O-ring, Teflon
700-890 ...........O-ring tool

Tip Size

Spray Material

Filter Type

.011 — .013 Lacquers and stains

100 mesh filter

.015 — .019 Oil and latex

60 mesh filter

.021 — .026 Heavy bodied latex and blockfillers

30 mesh filter

NOTE: Do not exceed the sprayer's recommended

maximum tip size.

Electronic

Control Assy

Indicator Lights

Assembly

800-278

BLACK/RED/WHITE

BLACK

RED

WHITE

BLUE/YELLOW

GRAY/PURPLE

Transducer

800-449

BLACK

WHITE

WHITE

BLUE

BROWN

BLACK

BLACK

ORANGE

ORANGE

GREEN

Wire Assembly

800-368

Ground to

Gear Housing

Circuit

Breaker

800-389

Plug

Relay

800-376

Potentiometer Assy

800-277

Motor

Electrical Schematic

NOTE: All electrical work

should be performed
by a Titan authorized
service center.

PRIME/SPRAY Valve Assembly
(P/N 800-915)

Item

Part #

Description

Quantity

1

700-823

Dowel pin ....................................................1

2

700-537

Gasket ........................................................1

3

222-012

O-ring, Teflon ..............................................1

4

221-012

O-ring, Viton................................................1

5

800-924

Valve housing .............................................1

6

700-697

Valve handle ...............................................1

7

700-759

Groove pin ..................................................1

8

700-721

O-ring, Viton................................................1

9

700-250

Valve stem ..................................................1

10

800-926

Spring .........................................................1

11

700-248

Valve retainer..............................................1

12

700-251

Cam base ...................................................1

Accessories

Airless Tip Selection

Tips are selected by the orifice size and fan width. The proper
selection is determined by the fan width required for a specific
job and by the orifice size that will supply the desired amount
of fluid and accomplish proper atomization.
For light viscosity fluids, smaller orifice tips generally are
desired. For heavier viscosity materials, larger orifice tips are
preferred. Please refer to the chart below.

NOTE: When using “HOT” solvents, replace Viton o-

ring (item 8) with optional Teflon o-ring (700-
897). Install with o-ring tool (700-890).

1

2

3

4

5

6

7

8

9

10

11

12

Advertising