Safety instructions, Troubleshooting guide, Save these instructions – WindChaser Products PACRWC-HP User Manual

Page 4

Advertising
background image

READ ALL INSTRUCTIONS BEFORE USING THE AIR
CONDITIONER
When using electrical appliances, basic precautions should
always be followed to reduce the risk of fire, electric shock,
and injury to persons, including the following:
1) Do not damage the power cord.
2) Never lay down the unit while it is working.
3) Always keep it in an upright position to avoid any

damage to the cooling system.

4) Operate this unit in an ambient temperature of 90

o

F

or lower.

5) Be sure that the air inlets and outlets are not blocked

or covered up.

6) Never place anything on top of the unit and do not

cover it with any kind of cloth while it is plugged in
or in-use.

7) Your air conditioner has been designed to be used only

in a house, office and similar conditions and it should
not be used for any other purpose.

8) Never connect the unit to a defective outlet.
9) This unit needs at least 12Amps of electricity to start it’s

compressor. Plug the unit into a properly grounded
dedicated 15Amps or greater outlet. Check your
breaker box to determine which circuit the outlet is on.

10) Make sure that the unit is correctly connected before

turning on the unit’s power.

11) Never unplug the air conditioner while it is working.

This could damage the electronic circuits.

12) To avoid tripping the circuit, DO NOT USE AN

EXTENSION CORD FOR THIS UNIT.

13) To turn on your unit, always use the switch on the

control panel.

14) Do not bend or crush the warm air exhaust hose.
15) It is dangerous to modify or to change the

characteristics of the unit.

16) Prevent children from climbing on the unit.
17) Do not place the air conditioner near curtains

(minimum distance 1.5 ft.).

18) Do not place the power cord under a carpet.
19) Never install the unit in direct sunshine or in the rain.
20) Keep the area around the warm air outlet sufficiently

clean and make sure that it is not congested.

21) For any repairs, refer directly to our customer service

department. Repairs carried out by unqualified people
may cause damage or may even be dangerous
and void the warranty.

Any damage resulting from failure to comply with these
instructions is excluded from the warranty.

SAVE THESE INSTRUCTIONS

This Portable Air Conditioner is electronically controlled,
which allows precise programming to adjust the room tem-
perature. This unit is a small appliance that adjusts the
temperature and humidity in a room. It’s flexibility makes it
easy to use in different applications and in various rooms.
This unit is designed for use in a home, office and comput-
er type room. This air conditioner allows you to control the
4 factors that determine optimal comfort in a room.

• Humidity Rate: the humidity in a room also causes

a sensation of stifling heat in the summer. Your air
conditioner not only cools down the temperature,
but dehumidifies the air as well.

• Heater: The air conditioner will function as a heater,

releasing warm air into the room.

• Temperature: the main function of an air conditioner

is to draw hot air out of the room.

• Airflow: The air conditioner regulates the airflow,

allowing the flow to be directed and ensuring
optimal air circulation

• The unit will not instantaneously cool down the

room once it is turned on. It will take the unit some

time to gradually cool down the room.

• Ion Generator: Cleans and freshens the air. Produces

Negative Ions For Clean and A Healthy Environment

*Note: Avoid being directly in front of the cold airflow and do
not direct it onto people.

Do not install and use your air conditioner before

completely reading these instructions. This will help you

optimize the operation of your air conditioner.

The following advice and instructions should be
followed closely:

1. Your unit must always be used in an upright

position because it contains a cooling agent.

2. After unpacking, place the unit upright to allow the

cooling agent to stabilize, and wait 3 hours before
use.

3. When used for the first time, and every time it is

turned on, it takes your unit up to 3 minutes to be
operational.

4. Before operating the unit, please install the drain plug

(see page 4 for instructions)

Failure to comply with these instructions may damage the
unit and would invalidate the WINDCHASER guarantee.

SAFETY INSTRUCTIONS

2

LEARN INTELLIGENT AIR

CONDITIONING

IMPORTANT INSTRUCTIONS

When the air conditioner does not work, it is sometimes a minor problem which the user can handle.
Before calling customer service, please check the following points to see if they solve your problem.
Additional troubleshooting tips may be found on our website at: www.windchaserproducts.com.

Problem

The air conditioner / dehumidifier
doesn’t work.

The air conditioner cuts off.

The WATER FULL LED indicator
light flashes.

The LED display shows the unit is set, but
the unit is not running.

Probable Causes

1) Plug not properly inserted into wall

outlet.

2) Insufficient amount of amperage to

start unit.

3) Water tank is full / alarm light

illuminated.

1) Exhaust hose too long, run

incorrectly or kinked.

2) Unit too close to wall

or object.

3) Ceiling or basement does

not have ample ventilation.

4) The “timer off” function

has been activated.

5) Room temperature is not between

61

o

-90

o

F.

The condensate tank is full and
the unit cannot drain. This safety feature
turns off the unit to protect the unit and
prevent the condensate tank from
overflowing.

The unit’s “timer on” feature is
activated.

Solutions

1) Plug the appliance in properly.

2) Check circuit breaker box for

15-20amp circuit availability.

3) Drain Unit.

1) Exhaust hose can only be

extended using max. 5’ of 4”
PVC pipe or flex ducting for a total
exhaust length of 10’.

2) Unit should be at least 1 ½’

away from walls and objects

3) Unit will overheat if the exhaust

cannot fully vent.

4) Push the power button to turn unit on.

5) Turn unit back on when room

temperature is between 61

o

-90

o

F.

Drain unit from the drain plug at the back
of the unit.

1) This is normal.

2) Push the Power button to turn the unit
on and deactivate the “timer on” feature.

TROUBLESHOOTING GUIDE

11

Advertising