INSTALLER/CONFIGURATION MENU

21

20

18

MENU

dS (On)

Off

Selects Automatic Daylight Saving Time option

22

21

19

MENU

(OFF)

Keypad Lockout

L, P, Limit

Selects one of 3 Keypad Lockout confi gurations

L - Total Keypad Lockout

P - Partial Keypad Lockout

(Up and Keys still work)

Limit - Limited Temperature RANGE

MENU

(000)

Keypad Lockout

1-999

Selects personal lockout code. 000 is NOT A

VALID CODE.

23

22

20

MENU

L Heat

(99)

L 62 to L 98

Select's Limited HEAT Range

24

23

21

MENU

L Cool

(45)

L 46 to L 82

Select's Limited COOL Range

25

24

MENU

CO

(05)

6-50

Selects outdoor Compressor OFF temperature

(Balance Point temperature). 05 disables fea-

ture. Outdoor Remote required

MENU

(dF)

EA

Selects between dF (dual Fuel) or EA (Electric

Aux) only available is CO > 6

MENU

cd

(60)

Selects Compressor delay OFF time in seconds

26

25

MENU

AO

(80)

Selects AO (Auxiliary OFF) temperature. Fea-

ture disabled is 80 selected. Outdoor Remote

required

27

26

22

MENU

(OFF) EC

On

Selects Economizer On/OFF

28

27

23

MENU

(O) pp

1-3

Selects no. of hours of preoccupancy purge time

(hours the Fan runs (C an A1 energized)

prior to occupied period)

29

28

24

MENU

Change Filter (OFF)

On

Selects Filter Change-out Indicator On or OFF.

MENU

Change Filter (200 h)

25-1975 h

Change Filter time in 25 hour increments. This
menu only appears if On is selected in above.

30

29

25

MENU

(OFF)

Change UV Lamp

On

Selects UV Lamp

Timer: On/OFF

MENU

(350)

Change UV Lamp

25-1975

Selects no. of Days between changing UV Lamp

31

30

26

MENU

Cool On (o)

Heat On (b)

Selects operation of the reversing valve terminal

(O/B) output as an O or B terminal

32 3

1 27 MENU RUN SCHED Returns to Normal Operation

1) This control can be confi gured for:

MS 2 – Multi-Stage System (no heat pump)

HP 1 – Heat Pump with one stage of compressor

HP 2 – Heat Pump with two stage compressor or two
compressor system, Gas or Electric backup

SS 1 – Single Stage System

2) GAS or Electric (ELE) fan operation. If the heating system

requires the thermostat to energize the fan, select ELE.
Select GAS if the heating system energizes the fan on a
call for heat.

3) Select Cool Savings™ value – Selects the amount of

adjustment for the Cool Savings™ feature in Cool mode
with 1 (1°) being the least amount of adjustment and 6
(6°) being the most amount of adjustment. Default value
is 3. Cool Savings is an optional energy saving feature that
can reduce your cooling costs. It is based on the principal
that lower indoor humidity makes a slightly higher tem-
perature feel more comfortable. Cool Savings operates
during periods of high demand which normally occur on
the hottest summer days when a cooling system may run
for hours to reach the thermostat setting. Long cooling
run times also lower the indoor humidity. Cool Savings,

very slowly, adjusts the setpoint temperature to make the
setpoint closer to the displayed room temperature, to a
maximum of the number of degrees you select. Adjust-
ing the setpoint temperature over a long cooling run time
allows the system to reach your set temperature and turn
off. The room temperature will actually be higher than the
thermostat displays but the reduction in humidity will allow
comfort at the slightly higher temperature.

To turn this feature on in the Cool mode press Cool
Savings
. The display will show “Save” next to the set-
point temperature. When Cool Savings is making adjust-
ments to the room temperature display “Save” will be
fl ashing and the displayed room temperature may vary
within the adjustment range you selected.

If

"Save" is not displayed and this feature is OFF, no

change will occur when the cooling system is continuously
running during periods of high demand.

4) Energy Management Recovery: (this step is skipped if

confi gured to be non-programmable).

Energy Management Recovery (E) On enables the ther-
mostat to start heating or cooling early to make the building
temperature reach the program setpoint at the time you