Dynamics Sections Controls (top to bottom)

1. Compressor (white knobs)

a. The compressor’s Ratio/Slope can be set from 1 to infinity (limiter).

b.

The

Threshold is variably adjustable from +10 dB to -20 dB.

c. When the Attack time switch is set to Slow (F.ATK off,) attack time is auto-
sensing and program dependent. In the Fast setting (F.ATK,) attack time will be
forced to 1 ms.

d. Release time is adjustable from 0.1 sec to 4 seconds.

2. Expander/Gate (green knobs)

a. The expander’s Threshold is variable from -30 dB to +10 dB

b.

Range is variable from 0 – 40 dB.

c. When the Attack time switch is set to Slow (F.ATK off,) attack time is auto-
sensing and program dependent. In the Fast setting (F.ATK,) attack time is 1 ms.

d.

Release time is adjustable from 0.1 sec to 4 seconds.

e.

The GATE switch toggles the section from an expander (default mode) into a

gate.